TY - JOUR
T1 - Validity of a customized submaximal treadmill protocol for determining VO2max
AU - Strom, Cody J.
AU - Pettitt, Robert W.
AU - Krynski, Luke M.
AU - Jamnick, Nicholas A.
AU - Hein, Charles J.
AU - Pettitt, Cherie D.
N1 - Publisher Copyright:
© 2018, Springer-Verlag GmbH Germany, part of Springer Nature.
PY - 2018/9/1
Y1 - 2018/9/1
N2 - Introduction: A customized submaximal exercise test for cycle ergometry was reported as a superior estimate of maximum oxygen uptake (VO2max) in comparison to the traditional YMCA ergometry test. Purpose: Following similar methodology, we sought to validate a customized submaximal treadmill test (CustomTM) compared with the widely used Bruce submaximal protocol. Methods: Participants (29 women and 21 men; age = 31.37 ± 11.44 year, BMI = 24.02 ± 3.03) performed a graded exercise test (GXT) with a subsequent exhaustive, square-wave bout for the verification of “true” VO2max. In counterbalanced order, subjects then completed submaximal protocols. The CustomTM protocol consisted of two 3-min stages estimated at 35 and 70% of VO2max, where VO2max was estimated with a linear regression equation utilizing sex, BMI, age, and self-reported physical activity. Results: VO2 values from the GXT and verification bout were 47.2 ± 7.7 and 47.0 ± 7.7 ml kg−1 min−1, respectively (ICC = 0.99, CV = 2.0%, TE = 0.83 ml kg−1 min−1), with the highest value used as “true” VO2max (47.7 ± 7.7 ml kg−1 min−1). Neither the Bruce (45.95 ± 6.97 ml kg−1 min−1) nor the CustomTM (47.3 ± 9.4 ml kg−1 min−1) protocol differed from “true” VO2max. The CustomTM had a “very large” measurement agreement with “true” VO2max (ICC = 0.78, CV of 9.1%, TE = 4.07 ml kg−1 min−1). Bruce had a “large” measurement agreement with “true” VO2max (ICC = 0.62, CV of 10.0%, TE = 4.51 ml kg−1 min−1). Conclusion: The CustomTM was superior to the Bruce protocol, because it included a stage below and above gas exchange threshold, yielded a better measurement agreement for “true” VO2max, and was more time efficient.
AB - Introduction: A customized submaximal exercise test for cycle ergometry was reported as a superior estimate of maximum oxygen uptake (VO2max) in comparison to the traditional YMCA ergometry test. Purpose: Following similar methodology, we sought to validate a customized submaximal treadmill test (CustomTM) compared with the widely used Bruce submaximal protocol. Methods: Participants (29 women and 21 men; age = 31.37 ± 11.44 year, BMI = 24.02 ± 3.03) performed a graded exercise test (GXT) with a subsequent exhaustive, square-wave bout for the verification of “true” VO2max. In counterbalanced order, subjects then completed submaximal protocols. The CustomTM protocol consisted of two 3-min stages estimated at 35 and 70% of VO2max, where VO2max was estimated with a linear regression equation utilizing sex, BMI, age, and self-reported physical activity. Results: VO2 values from the GXT and verification bout were 47.2 ± 7.7 and 47.0 ± 7.7 ml kg−1 min−1, respectively (ICC = 0.99, CV = 2.0%, TE = 0.83 ml kg−1 min−1), with the highest value used as “true” VO2max (47.7 ± 7.7 ml kg−1 min−1). Neither the Bruce (45.95 ± 6.97 ml kg−1 min−1) nor the CustomTM (47.3 ± 9.4 ml kg−1 min−1) protocol differed from “true” VO2max. The CustomTM had a “very large” measurement agreement with “true” VO2max (ICC = 0.78, CV of 9.1%, TE = 4.07 ml kg−1 min−1). Bruce had a “large” measurement agreement with “true” VO2max (ICC = 0.62, CV of 10.0%, TE = 4.51 ml kg−1 min−1). Conclusion: The CustomTM was superior to the Bruce protocol, because it included a stage below and above gas exchange threshold, yielded a better measurement agreement for “true” VO2max, and was more time efficient.
KW - Bruce protocol
KW - Maximum oxygen uptake
KW - Treadmill testing
KW - VO slow component
UR - http://www.scopus.com/inward/record.url?scp=85048261371&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85048261371&partnerID=8YFLogxK
U2 - 10.1007/s00421-018-3908-x
DO - 10.1007/s00421-018-3908-x
M3 - Article
C2 - 29948196
AN - SCOPUS:85048261371
SN - 1439-6319
VL - 118
SP - 1781
EP - 1787
JO - European Journal of Applied Physiology
JF - European Journal of Applied Physiology
IS - 9
ER -