Validation of a double-semicircular notched configuration for mechanical testing of orthodontic thermoplastic aligner materials

Yuqing Zhang, Xiaozhuang Jin, Fabio Savoldi, Jianmin Han, Ray Kai Leung Su, Alex Fok, Jiang Chen, James Kit Hon Tsoi

Research output: Contribution to journalArticlepeer-review

Abstract

The potential of using specimens with a double-semicircular-notched configuration for performing tensile tests of orthodontic thermoplastic aligner materials was explored. Unnotched and double-semicircular-notched specimens were loaded in tension using a universal testing machine to determine their tensile strength, while finite element analysis (FEA) and digital image correlation (DIC) were used to estimate stress and strain, respectively. The shape did affect the tensile strength, demonstrating the importance of unifying the form of the specimen. During the elastic phase under tension, double-semicircular-notched specimens showed similar behavior to unnotched specimens. However, great variance was observed in the strain patterns of the unnotched specimens, which exhibited greater chance of end-failure, while the strain patterns of the double-semicircular-notched specimens showed uniformity. Considerable agreement between the theoretical (FEA) and practical models (DIC) further confirmed the validity of the double-semicircular-notched models.

Original languageEnglish (US)
Article number106543
JournalJournal of the Mechanical Behavior of Biomedical Materials
Volume155
DOIs
StatePublished - Jul 2024

Bibliographical note

Publisher Copyright:
© 2024 Elsevier Ltd

Keywords

  • Clear aligner
  • Digital image correlation
  • Finite element analysis
  • Tensile strength
  • Thermoplastic

PubMed: MeSH publication types

  • Journal Article
  • Validation Study