Use of the Centaur TnI-Ultra assay for detection of myocardial infarction and adverse events in patients presenting with symptoms suggestive of acute coronary syndrome

  • Fred S. Apple
  • , Stephen W. Smith
  • , Lesly A. Pearce
  • , Ranka Ler
  • , Maryann M. Murakami

Research output: Contribution to journalArticlepeer-review

Abstract

BACKGROUND: We determined the diagnostic accuracy of the Advia Centaur TnI-Ultra assay for detecting myocardial infarction (MI) and assessing risk of adverse events in patients presenting with ischemic symptoms suggestive of acute coronary syndrome. METHODS: We measured cardiac troponin I (cTnI) on admission and 6-24 h after admission (follow-up) in plasma specimens from 371 consecutive patients. The end point was the first of cardiac event or death within 60 days. We estimated survival curves using the Kaplan-Meier method and compared groups with the log rank statistic. RESULTS: MI was established in 49 patients (13%). Clinical sensitivities and specificities for MI based on the 99th percentile (0.04μg/L) were 74% and 84%, respectively, on admission and 94% and 81% at follow-up. ROC curves showed significantly higher accuracy for MI in the follow-up specimen compared with admission (P = 0.001). Overall there were 2 cardiac deaths, 1 noncardiac death, 49 MIs, 7 coronary artery bypass grafts, and 36 percutaneous coronary interventions in 59 patients during follow-up. The event rate in those with cTnI <0.006 μg/L was significantly lower than in groups with cTnI 0.006-0.04 μg/L, >0.04-0.10 μg/L, or >0.10 μg/L (2.8% vs 11.1%, 24.1%, 55.1%, respectively; P <0.0001). Relative risks for the increasing cTnI cutoff groups were 3.9 (95% CI 1.2-13), 8.9 (2.4-34), and 25 (7.3- 82) after adjustment for age, diabetes, history of hypertension, previous MI, and estimated glomerular filtration rate. CONCLUSIONS: The TnI-Ultra assay is a sensitive, early diagnostic biomarker for MI and an independent predictor of adverse events at any measurable cTnI in patients with symptoms of acute coronary syndrome.

Original languageEnglish (US)
Pages (from-to)723-728
Number of pages6
JournalClinical chemistry
Volume54
Issue number4
DOIs
StatePublished - Apr 1 2008

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'Use of the Centaur TnI-Ultra assay for detection of myocardial infarction and adverse events in patients presenting with symptoms suggestive of acute coronary syndrome'. Together they form a unique fingerprint.

Cite this