TY - JOUR
T1 - Two-Year Results of PROACTIVE-HF Trial Stratified by Left Ventricular Ejection Fraction
AU - GUICHARD, JASON L.
AU - BONNO, ERIC L.
AU - NASSIF, MICHAEL E.
AU - KHUMRI, TAIYEB M.
AU - MIRANDA, DAVID
AU - JONSSON, ORVAR
AU - SHAH, HIRAK
AU - ALEXY, TAMAS
AU - MACALUSO, GREGORY P.
AU - HICKEY, GAVIN
AU - McCANN, P. A.T.R.I.C.K.
AU - COWGER, JENNIFER A.
AU - BADIYE, AMIT
AU - RAZA, YASMIN
AU - MASHA, LUKE
AU - KUNAVARAPU, CHANDRA
AU - BENNETT, MOSI
AU - SHARIF, FAISAL
AU - KIERNAN, MICHAEL
AU - MULLENS, WILFRIED
AU - CHAPARRO, SANDRA V.
AU - MAHR, CLAUDIUS
AU - AMIN, ROHIT R.
AU - STEVENSON, LYNNE WARNER
AU - KLEIN, LIVIU
N1 - Publisher Copyright:
© 2026 The Authors.
PY - 2026
Y1 - 2026
N2 - Background In the PROACTIVE-HF trial, remote heart failure (HF) management using comprehensive vital signs and seated mean pulmonary artery pressure (mPAP) was safe and resulted in a low reported rate of HF hospitalization (HFH) and all-cause mortality (HFH/D) through 12 months. In this report, we extend the results from the PROACTIVE-HF study through 2 years, stratified by ejection fraction (EF). Methods and Results PROACTIVE-HF was a prospective, multicenter, open-label, single-arm trial evaluating the safety and efficacy of patient management using the Cordella PA pressure sensor system in patients with New York Heart Association class III symptoms, regardless of EF. In the first 24 months, the incidence of HF events (HFE)/D was 0.89 (95% CI 0.81−0.99) events per patient, driven by HFH. Patients with HF with reduced EF had greater HFE/D rates than those with HF with preserved EF (1.0 vs 0.8 events per patient, P = .048). Conclusions For patients with HF experiencing moderate-to-severe symptoms, management using the Cordella PA sensor system was associated with low event rates and improved health status at 2 years, regardless of EF. Comprehensive remote monitoring of vital signs, seated PAP, and patient-reported symptoms via a digital platform supports sustained benefit for high-risk patients with HF.
AB - Background In the PROACTIVE-HF trial, remote heart failure (HF) management using comprehensive vital signs and seated mean pulmonary artery pressure (mPAP) was safe and resulted in a low reported rate of HF hospitalization (HFH) and all-cause mortality (HFH/D) through 12 months. In this report, we extend the results from the PROACTIVE-HF study through 2 years, stratified by ejection fraction (EF). Methods and Results PROACTIVE-HF was a prospective, multicenter, open-label, single-arm trial evaluating the safety and efficacy of patient management using the Cordella PA pressure sensor system in patients with New York Heart Association class III symptoms, regardless of EF. In the first 24 months, the incidence of HF events (HFE)/D was 0.89 (95% CI 0.81−0.99) events per patient, driven by HFH. Patients with HF with reduced EF had greater HFE/D rates than those with HF with preserved EF (1.0 vs 0.8 events per patient, P = .048). Conclusions For patients with HF experiencing moderate-to-severe symptoms, management using the Cordella PA sensor system was associated with low event rates and improved health status at 2 years, regardless of EF. Comprehensive remote monitoring of vital signs, seated PAP, and patient-reported symptoms via a digital platform supports sustained benefit for high-risk patients with HF.
UR - https://www.scopus.com/pages/publications/105035490264
UR - https://www.scopus.com/pages/publications/105035490264#tab=citedBy
U2 - 10.1016/j.cardfail.2026.01.023
DO - 10.1016/j.cardfail.2026.01.023
M3 - Article
C2 - 41833749
AN - SCOPUS:105035490264
SN - 1071-9164
JO - Journal of cardiac failure
JF - Journal of cardiac failure
ER -