TY - JOUR
T1 - Tracking the optic nerve head in OCT video using dual eigenspaces and an adaptive vascular distribution model
AU - Koozekanani, Dara
AU - Boyer, Kim
AU - Roberts, Cynthia
AU - Katz, Steven
PY - 2001
Y1 - 2001
N2 - Optical coherence tomography (OCT) is a new ophthalmic imaging modality generating cross sectional views of the retina. OCT systems form images in 1.5 seconds by directing a superluminescent diode (SLD) beam over the retinal surface. Involuntary ocular motion may occur, however, causing incorrect locations to be imaged. This motion may leave no obvious artifacts and thus go undetected. For glaucoma monitoring especially, knowing the measurement location is crucial. The commercially available OCT system displays a near-IR video of the SLD beam traversing the retinal around the optic nerve head. We developed a prototype system to detect the nerve head and SLD beam position in this video, and report the actual scan path relative to the nerve head. This system must cope with low image contrast and few reliable retinal features. In its adaptive model generation phase, the system directly detects vasculature and the nerve head and builds an individual model of the vascular pattern. The nerve head identification is multitiered, using a novel, dual-eigenspace technique and a geometric comparison of detected vessel positions and nerve head hypotheses. In its operational phase, a correspondence is achieved between detected vasculature and the model. The system was evaluated on video of three subjects not used to form the eigenspaces. The system located the optic nerve head to within 5 pixels in 99% of 2800 video fields manually inspected, and was thus able to determine the true scan path relative to the nerve head.
AB - Optical coherence tomography (OCT) is a new ophthalmic imaging modality generating cross sectional views of the retina. OCT systems form images in 1.5 seconds by directing a superluminescent diode (SLD) beam over the retinal surface. Involuntary ocular motion may occur, however, causing incorrect locations to be imaged. This motion may leave no obvious artifacts and thus go undetected. For glaucoma monitoring especially, knowing the measurement location is crucial. The commercially available OCT system displays a near-IR video of the SLD beam traversing the retinal around the optic nerve head. We developed a prototype system to detect the nerve head and SLD beam position in this video, and report the actual scan path relative to the nerve head. This system must cope with low image contrast and few reliable retinal features. In its adaptive model generation phase, the system directly detects vasculature and the nerve head and builds an individual model of the vascular pattern. The nerve head identification is multitiered, using a novel, dual-eigenspace technique and a geometric comparison of detected vessel positions and nerve head hypotheses. In its operational phase, a correspondence is achieved between detected vasculature and the model. The system was evaluated on video of three subjects not used to form the eigenspaces. The system located the optic nerve head to within 5 pixels in 99% of 2800 video fields manually inspected, and was thus able to determine the true scan path relative to the nerve head.
UR - http://www.scopus.com/inward/record.url?scp=0035686825&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0035686825&partnerID=8YFLogxK
M3 - Conference article
AN - SCOPUS:0035686825
SN - 1063-6919
VL - 1
SP - I934-I941
JO - Proceedings of the IEEE Computer Society Conference on Computer Vision and Pattern Recognition
JF - Proceedings of the IEEE Computer Society Conference on Computer Vision and Pattern Recognition
T2 - 2001 IEEE Computer Society Conference on Computer Vision and Pattern Recognition
Y2 - 8 December 2001 through 14 December 2001
ER -