TY - JOUR
T1 - Toric intraocular lens orientation and residual refractive astigmatism
T2 - An analysis
AU - Potvin, Rick
AU - Kramer, Brent A.
AU - Hardten, David R.
AU - Berdahl, John P.
N1 - Publisher Copyright:
© 2016 Potvin et al.
PY - 2016/9/20
Y1 - 2016/9/20
N2 - Purpose: To analyze intraocular lens (IOL) orientation data from an online toric back-calculator (astigmatismfix.com) for determining if differences were apparent by lens type. Methods: A retrospective review of astigmatismfix.com toric back-calculations that included IOL identification and intended orientation axis. Results: Of 12,812 total validated calculation records, 8,229 included intended orientation and lens identification data. Of the latter, 5,674 calculations (69%) involved lenses oriented 5° or more from their intended position. Using estimated toric lens usage data, the percentage of lenses with orientation ≥5° from intended was 0.89% overall, but the percentage varied significantly between specific toric lens brands (P<0.05). The percentage of back-calculations related to lenses that were not oriented as intended was also statistically significantly different by lens brand (P<0.05). When IOLs were misoriented, they were significantly more likely to be misoriented in a counterclockwise direction (P<0.05). This was found to be due to a bias toward counterclockwise orientation observed with one specific brand, a bias that was not observed with the other three brands analyzed here. Conclusion: The percentage of eyes with lens orientation ≥5° from intended in the Toric Results Analyzer data set was <1% of toric IOLs in general, with the relative percentage of Tecnis ® Toric IOLs significantly higher than AcrySof ® Toric IOLs. Both of these had higher rates than the Staar ® Toric and Trulign ® Toric lenses, with the availability of higher Tecnis and AcrySof cylinder powers a likely contributing factor. The AcrySof Toric IOL appears to be less likely than the Tecnis Toric IOL to cause residual astigmatism as a result of misori-entation. The Tecnis Toric IOL appears more likely to be misoriented in a counterclockwise direction; no such bias was observed with the AcrySof Toric, the Trulign ® Toric, or the Staar Toric IOLs.
AB - Purpose: To analyze intraocular lens (IOL) orientation data from an online toric back-calculator (astigmatismfix.com) for determining if differences were apparent by lens type. Methods: A retrospective review of astigmatismfix.com toric back-calculations that included IOL identification and intended orientation axis. Results: Of 12,812 total validated calculation records, 8,229 included intended orientation and lens identification data. Of the latter, 5,674 calculations (69%) involved lenses oriented 5° or more from their intended position. Using estimated toric lens usage data, the percentage of lenses with orientation ≥5° from intended was 0.89% overall, but the percentage varied significantly between specific toric lens brands (P<0.05). The percentage of back-calculations related to lenses that were not oriented as intended was also statistically significantly different by lens brand (P<0.05). When IOLs were misoriented, they were significantly more likely to be misoriented in a counterclockwise direction (P<0.05). This was found to be due to a bias toward counterclockwise orientation observed with one specific brand, a bias that was not observed with the other three brands analyzed here. Conclusion: The percentage of eyes with lens orientation ≥5° from intended in the Toric Results Analyzer data set was <1% of toric IOLs in general, with the relative percentage of Tecnis ® Toric IOLs significantly higher than AcrySof ® Toric IOLs. Both of these had higher rates than the Staar ® Toric and Trulign ® Toric lenses, with the availability of higher Tecnis and AcrySof cylinder powers a likely contributing factor. The AcrySof Toric IOL appears to be less likely than the Tecnis Toric IOL to cause residual astigmatism as a result of misori-entation. The Tecnis Toric IOL appears more likely to be misoriented in a counterclockwise direction; no such bias was observed with the AcrySof Toric, the Trulign ® Toric, or the Staar Toric IOLs.
KW - AcrySof
KW - Cylinder
KW - Rotation
KW - Tecnis
KW - Toric back calculator
UR - http://www.scopus.com/inward/record.url?scp=84988697022&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84988697022&partnerID=8YFLogxK
U2 - 10.2147/OPTH.S114118
DO - 10.2147/OPTH.S114118
M3 - Article
AN - SCOPUS:84988697022
SN - 1177-5467
VL - 10
SP - 1829
EP - 1836
JO - Clinical Ophthalmology
JF - Clinical Ophthalmology
ER -