Thermal conductivity, thermal diffusivity and specific heat were measured for shucked oysters. Thermal conductivity increased from 0.577 to 0.677 W/m°C as temperature increased from 0 to 50°C measured by a line heat source thermal conductivity probe. Specific heat was measured using a differential scanning calorimeter. It increased from 3.795 to 4.047 kJ/kg°C when temperature was raised from 10 to 50°C. Thermal diffusivity of oysters was calculated from thermal conductivity, specific heat and density values. Dielectric properties of oysters were determined by an open-ended coaxial cable connected to a network analyser between 300 MHz and 3 GHz. At microwave frequencies of 915 and 2450 MHz, it was observed that the dielectric constant decreased (64.02-50.89 at 915 MHz and 59.10-47.67 at 2450 MHz), while the loss factor increased (13.84-20.14) at 915 MHz as temperature increased from 1 to 55°C. Models were developed to describe the temperature effects on thermal and dielectric properties of shucked oysters.

Original languageEnglish (US)
Pages (from-to)489-494
Number of pages6
JournalLWT - Food Science and Technology
Volume38
Issue number5
DOIs
StatePublished - Aug 1 2005

Fingerprint

Ostreidae
dielectric properties
thermal conductivity
thermal properties
specific heat
oysters
Thermal Conductivity
Hot Temperature
thermal diffusivity
temperature
Temperature
calorimeters
cables (equipment)
probes (equipment)
heat
Microwaves

Keywords

  • Dielectric properties
  • Oysters
  • Specific heat
  • Thermal conductivity
  • Thermal diffusivity

Cite this

Thermal and dielectric properties of shucked oysters. / Hu, Xiaopei; Mallikarjunan, Parameswarakumar.

In: LWT - Food Science and Technology, Vol. 38, No. 5, 01.08.2005, p. 489-494.

Research output: Contribution to journalArticle

@article{1d1a2570802f41998fa0b08fc5697e38,
title = "Thermal and dielectric properties of shucked oysters",
abstract = "Thermal conductivity, thermal diffusivity and specific heat were measured for shucked oysters. Thermal conductivity increased from 0.577 to 0.677 W/m°C as temperature increased from 0 to 50°C measured by a line heat source thermal conductivity probe. Specific heat was measured using a differential scanning calorimeter. It increased from 3.795 to 4.047 kJ/kg°C when temperature was raised from 10 to 50°C. Thermal diffusivity of oysters was calculated from thermal conductivity, specific heat and density values. Dielectric properties of oysters were determined by an open-ended coaxial cable connected to a network analyser between 300 MHz and 3 GHz. At microwave frequencies of 915 and 2450 MHz, it was observed that the dielectric constant decreased (64.02-50.89 at 915 MHz and 59.10-47.67 at 2450 MHz), while the loss factor increased (13.84-20.14) at 915 MHz as temperature increased from 1 to 55°C. Models were developed to describe the temperature effects on thermal and dielectric properties of shucked oysters.",
keywords = "Dielectric properties, Oysters, Specific heat, Thermal conductivity, Thermal diffusivity",
author = "Xiaopei Hu and Parameswarakumar Mallikarjunan",
year = "2005",
month = "8",
day = "1",
doi = "10.1016/j.lwt.2004.07.016",
language = "English (US)",
volume = "38",
pages = "489--494",
journal = "LWT - Food Science and Technology",
issn = "0023-6438",
publisher = "Academic Press Inc.",
number = "5",

}

TY - JOUR

T1 - Thermal and dielectric properties of shucked oysters

AU - Hu, Xiaopei

AU - Mallikarjunan, Parameswarakumar

PY - 2005/8/1

Y1 - 2005/8/1

N2 - Thermal conductivity, thermal diffusivity and specific heat were measured for shucked oysters. Thermal conductivity increased from 0.577 to 0.677 W/m°C as temperature increased from 0 to 50°C measured by a line heat source thermal conductivity probe. Specific heat was measured using a differential scanning calorimeter. It increased from 3.795 to 4.047 kJ/kg°C when temperature was raised from 10 to 50°C. Thermal diffusivity of oysters was calculated from thermal conductivity, specific heat and density values. Dielectric properties of oysters were determined by an open-ended coaxial cable connected to a network analyser between 300 MHz and 3 GHz. At microwave frequencies of 915 and 2450 MHz, it was observed that the dielectric constant decreased (64.02-50.89 at 915 MHz and 59.10-47.67 at 2450 MHz), while the loss factor increased (13.84-20.14) at 915 MHz as temperature increased from 1 to 55°C. Models were developed to describe the temperature effects on thermal and dielectric properties of shucked oysters.

AB - Thermal conductivity, thermal diffusivity and specific heat were measured for shucked oysters. Thermal conductivity increased from 0.577 to 0.677 W/m°C as temperature increased from 0 to 50°C measured by a line heat source thermal conductivity probe. Specific heat was measured using a differential scanning calorimeter. It increased from 3.795 to 4.047 kJ/kg°C when temperature was raised from 10 to 50°C. Thermal diffusivity of oysters was calculated from thermal conductivity, specific heat and density values. Dielectric properties of oysters were determined by an open-ended coaxial cable connected to a network analyser between 300 MHz and 3 GHz. At microwave frequencies of 915 and 2450 MHz, it was observed that the dielectric constant decreased (64.02-50.89 at 915 MHz and 59.10-47.67 at 2450 MHz), while the loss factor increased (13.84-20.14) at 915 MHz as temperature increased from 1 to 55°C. Models were developed to describe the temperature effects on thermal and dielectric properties of shucked oysters.

KW - Dielectric properties

KW - Oysters

KW - Specific heat

KW - Thermal conductivity

KW - Thermal diffusivity

UR - http://www.scopus.com/inward/record.url?scp=14944364707&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=14944364707&partnerID=8YFLogxK

U2 - 10.1016/j.lwt.2004.07.016

DO - 10.1016/j.lwt.2004.07.016

M3 - Article

AN - SCOPUS:14944364707

VL - 38

SP - 489

EP - 494

JO - LWT - Food Science and Technology

JF - LWT - Food Science and Technology

SN - 0023-6438

IS - 5

ER -