Abstract
A patient developed disseminated adenovirus infection following bone marrow transplant. TaqMan real-time PCR showed reduced maximum fluorescence in the amplification curve from all plasma samples. Sequencing revealed three single nucleotide mismatches between the TaqMan probe and probe binding region. Real-time PCR with probe matching the isolate sequence showed normal amplification and a higher copy number result.
| Original language | English (US) |
|---|---|
| Pages (from-to) | 40-43 |
| Number of pages | 4 |
| Journal | Diagnostic Microbiology and Infectious Disease |
| Volume | 89 |
| Issue number | 1 |
| DOIs | |
| State | Published - Sep 2017 |
| Externally published | Yes |
Bibliographical note
Publisher Copyright:© 2017 Elsevier Inc.
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 3 Good Health and Well-being
Keywords
- Aberrant real-time PCR
- Adenovirus
- Reduced fluorescence
Fingerprint