TY - JOUR
T1 - The compressive strength of nonprecious versus precious ceramometal restorations with various frame designs
AU - Marker, John C.
AU - Goodkind, Richard J.
AU - Gerberich, William W
PY - 1986/5
Y1 - 1986/5
N2 - This study was designed as a comparative analysis of the compressive strengths of precious versus nonprecious metals with various framework designs used in clinical restorations. One hundred thirty-five statistically uniform ceramometal restorations were fabricated. The restorations were cemented to the die and then subjected to stroke-control compression forces in an Instron loading machine. Simulated clinical failure was recorded by the Instron load cell recorder in pounds of load.
AB - This study was designed as a comparative analysis of the compressive strengths of precious versus nonprecious metals with various framework designs used in clinical restorations. One hundred thirty-five statistically uniform ceramometal restorations were fabricated. The restorations were cemented to the die and then subjected to stroke-control compression forces in an Instron loading machine. Simulated clinical failure was recorded by the Instron load cell recorder in pounds of load.
UR - http://www.scopus.com/inward/record.url?scp=0022718493&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0022718493&partnerID=8YFLogxK
U2 - 10.1016/0022-3913(86)90031-4
DO - 10.1016/0022-3913(86)90031-4
M3 - Article
C2 - 3519943
AN - SCOPUS:0022718493
SN - 0022-3913
VL - 55
SP - 560
EP - 567
JO - Journal of Prosthetic Dentistry
JF - Journal of Prosthetic Dentistry
IS - 5
ER -