    Abstract

    Background: With continued evolution in stereotactic techniques and an expanding armamentarium of surgical therapeutic options, non-craniotomy stereotactic procedures in neuro-oncology are becoming increasingly complex, often requiring multi-trajectory approaches. Here we demonstrate that the ClearPoint SmartFrame Array (Solana Beach, California, USA), a second-generation magnetic resonance imaging–compatible stereotactic frame, supports such non-craniotomy, multi-trajectory (NCMT) stereotactic procedures. Methods: We previously published case reports demonstrating the feasibility of NCMT through the ClearPoint SmartFrame Array. Here we prospectively followed the next 10 consecutive patients who underwent such multi-trajectory procedures to further establish procedural safety and clinical utility. Results: Ten patients underwent complex, multi-trajectory stereotactic procedures, including combinations of needle biopsy ± cyst drainage and laser interstitial thermal therapy targeting geographically distinct regions of neoplastic lesions under the same anesthetic event. The median maximal radial error of stereotaxis was 1.0 mm. In all cases, definitive diagnosis was achieved, and >90% of the intended targets were ablated. The average stereotaxis time for the multi-trajectory procedure was 119 ± 22.2 minutes, comparing favorably to our previously published results of single-trajectory procedures (80 ± 9.59 minutes, P = 0.125). There were no procedural complications. Post-procedure, the neurologic condition of 1 patient improved, while the remaining 9 patients remained stable. All patients were discharged home, with a median hospital stay of 1 day (range: 1–12 days). With a median follow-up of 376 days (range: 155–1438 days), there were no 30-day readmissions or wound complications. Conclusions: Geographically distinct regions of brain cancer can be safely and accurately accessed through the ClearPoint Array frame in NCMT stereotactic procedures.

    Original languageEnglish (US)
    Pages (from-to)e754-e764
    JournalWorld Neurosurgery
    Volume184
    DOIs
    StatePublished - Apr 2024

    Bibliographical note

    Publisher Copyright:
    © 2024 Elsevier Inc.

    UN SDGs

    This output contributes to the following UN Sustainable Development Goals (SDGs)

    1. SDG 3 - Good Health and Well-being
      SDG 3 Good Health and Well-being

    Keywords

    • LITT
    • Neuro-oncology
    • Stereotactic surgery
    • Technology

    Fingerprint

    Dive into the research topics of 'The ClearPoint Array Frame: An MRI Compatible System that Supports Non-craniotomy, Multi-trajectory (NCMT) Stereotactic Procedures'. Together they form a unique fingerprint.

    Cite this