Abstract
The abrasion resistance of six restorative materials was determined by two different test methods. The dependence of abrasion resistance on the hardness of the material was different in the two cases. A tentative explanation is offered for this difference in behaviour and its potential clinical significance is considered.
Original language | English (US) |
---|---|
Pages (from-to) | 233-238 |
Number of pages | 6 |
Journal | Journal of Dentistry |
Volume | 6 |
Issue number | 3 |
DOIs | |
State | Published - Sep 1978 |