TY - JOUR
T1 - Synthesizing Virtual Oscillators to Control Islanded Inverters
AU - Johnson, Brian B.
AU - Sinha, Mohit
AU - Ainsworth, Nathan G.
AU - Dorfler, Florian
AU - Dhople, Sairaj V.
N1 - Publisher Copyright:
© 1986-2012 IEEE.
PY - 2016/8
Y1 - 2016/8
N2 - Virtual oscillator control (VOC) is a decentralized control strategy for islanded microgrids where inverters are regulated to emulate the dynamics of weakly nonlinear oscillators. Compared to droop control, which is only well defined in sinusoidal steady state, VOC is a time-domain controller that enables interconnected inverters to stabilize arbitrary initial conditions to a synchronized sinusoidal limit cycle. However, the nonlinear oscillators that are elemental to VOC cannot be designed with conventional linear-control design methods. We address this challenge by applying averaging-and perturbation-based nonlinear analysis methods to extract the sinusoidal steady-state and harmonic behavior of such oscillators. The averaged models reveal conclusive links between real-and reactive-power outputs and the terminal-voltage dynamics. Similarly, the perturbation methods aid in quantifying higher order harmonics. The resultant models are then leveraged to formulate a design procedure for VOC such that the inverter satisfies standard ac performance specifications related to voltage regulation, frequency regulation, dynamic response, and harmonic content. Experimental results for a single-phase 750 VA, 120 V laboratory prototype demonstrate the validity of the design approach. They also demonstrate that droop laws are, in fact, embedded within the equilibria of the nonlinear-oscillator dynamics. This establishes the backward compatibility of VOC in that, while acting on time-domain waveforms, it subsumes droop control in sinusoidal steady state.
AB - Virtual oscillator control (VOC) is a decentralized control strategy for islanded microgrids where inverters are regulated to emulate the dynamics of weakly nonlinear oscillators. Compared to droop control, which is only well defined in sinusoidal steady state, VOC is a time-domain controller that enables interconnected inverters to stabilize arbitrary initial conditions to a synchronized sinusoidal limit cycle. However, the nonlinear oscillators that are elemental to VOC cannot be designed with conventional linear-control design methods. We address this challenge by applying averaging-and perturbation-based nonlinear analysis methods to extract the sinusoidal steady-state and harmonic behavior of such oscillators. The averaged models reveal conclusive links between real-and reactive-power outputs and the terminal-voltage dynamics. Similarly, the perturbation methods aid in quantifying higher order harmonics. The resultant models are then leveraged to formulate a design procedure for VOC such that the inverter satisfies standard ac performance specifications related to voltage regulation, frequency regulation, dynamic response, and harmonic content. Experimental results for a single-phase 750 VA, 120 V laboratory prototype demonstrate the validity of the design approach. They also demonstrate that droop laws are, in fact, embedded within the equilibria of the nonlinear-oscillator dynamics. This establishes the backward compatibility of VOC in that, while acting on time-domain waveforms, it subsumes droop control in sinusoidal steady state.
KW - Averaging
KW - Droop control
KW - Microgrids,
KW - Nonlinear oscillator circuits
KW - Synchronization
KW - Van der Pol oscillators
UR - http://www.scopus.com/inward/record.url?scp=84963768442&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84963768442&partnerID=8YFLogxK
U2 - 10.1109/TPEL.2015.2497217
DO - 10.1109/TPEL.2015.2497217
M3 - Article
AN - SCOPUS:84963768442
SN - 0885-8993
VL - 31
SP - 6002
EP - 6015
JO - IEEE Transactions on Power Electronics
JF - IEEE Transactions on Power Electronics
IS - 8
M1 - 7317584