TY - JOUR
T1 - Synchronized Pulsatile Flow With Low Systolic Output From Veno-Arterial Extracorporeal Membrane Oxygenation Improves Myocardial Recovery After Experimental Cardiac Arrest in Pigs
AU - Voicu, Sebastian
AU - Sideris, Georgios
AU - Dillinger, Jean Guillaume
AU - Yannopoulos, Demetris
AU - Deye, Nicolas
AU - Kang, Chantal
AU - Bonneau, Michel
AU - Bartos, Jason
AU - Kedra, Antoni
AU - Bailliart, Sophie
AU - Pasteur-Rousseau, Adrien
AU - Amah, Guy
AU - Bonnin, Philippe
AU - Callebert, Jacques
AU - Henry, Patrick
AU - Megarbane, Bruno
N1 - Publisher Copyright:
© 2018 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
PY - 2018/6
Y1 - 2018/6
N2 - Circulatory failure following cardiac arrest (CA) requires catecholamine support and occasionally veno-arterial extracorporeal membrane oxygenation (vaECMO). VaECMO-generated blood flow is continuous and retrograde, increasing ventricular stroke work. Our aim was to assess the benefit of a device generating a pulsatile vaECMO flow synchronized with the heart rhythm lowering systolic vaECMO output on the left ventricular ejection fraction (LVEF) and pulmonary capillary pressure (Pcap) after CA. This experimental randomized study in pigs compared standard nonpulsatile vaECMO (control) with pulsatile synchronized vaECMO (study) group using a pulsatility-generating device. After sedation and intubation, ventricular fibrillation was induced by pacing. After 10-min ventricular fibrillation, cardiopulmonary resuscitation was performed for 20 min then vaECMO, defibrillation and 0.15 µg/kg/min intravenous epinephrine infusion were initiated. Hemodynamics, Pcap, LVEF by echocardiography and angiography were measured at baseline and every 30 min after the vaECMO start until vaECMO and epinephrine were stopped (at 120 min), and 30 min later. Baseline hemodynamics did not differ between groups; 120 min after vaECMO initiation, LVEF by echocardiography and angiography was significantly higher in the study than control group 55 ± 19% versus 34 ± 13% (P = 0.042), 50 ± 16% versus 33 ± 12% (P = 0.043), respectively. Pcap decreased from baseline by 4.2 ± 8.6 mm Hg in the study group but increased by 5.6 ± 5.9 mm Hg in the control group (P = 0.043). Thirty minutes later, LVEF remained higher in the study group 44 ± 7% versus 26 ± 11% (P = 0.008) while Pcap did not differ. A synchronized pulsatile device decreasing systolic output from vaECMO improved LVEF and Pcap in a pig model of CA and resuscitation.
AB - Circulatory failure following cardiac arrest (CA) requires catecholamine support and occasionally veno-arterial extracorporeal membrane oxygenation (vaECMO). VaECMO-generated blood flow is continuous and retrograde, increasing ventricular stroke work. Our aim was to assess the benefit of a device generating a pulsatile vaECMO flow synchronized with the heart rhythm lowering systolic vaECMO output on the left ventricular ejection fraction (LVEF) and pulmonary capillary pressure (Pcap) after CA. This experimental randomized study in pigs compared standard nonpulsatile vaECMO (control) with pulsatile synchronized vaECMO (study) group using a pulsatility-generating device. After sedation and intubation, ventricular fibrillation was induced by pacing. After 10-min ventricular fibrillation, cardiopulmonary resuscitation was performed for 20 min then vaECMO, defibrillation and 0.15 µg/kg/min intravenous epinephrine infusion were initiated. Hemodynamics, Pcap, LVEF by echocardiography and angiography were measured at baseline and every 30 min after the vaECMO start until vaECMO and epinephrine were stopped (at 120 min), and 30 min later. Baseline hemodynamics did not differ between groups; 120 min after vaECMO initiation, LVEF by echocardiography and angiography was significantly higher in the study than control group 55 ± 19% versus 34 ± 13% (P = 0.042), 50 ± 16% versus 33 ± 12% (P = 0.043), respectively. Pcap decreased from baseline by 4.2 ± 8.6 mm Hg in the study group but increased by 5.6 ± 5.9 mm Hg in the control group (P = 0.043). Thirty minutes later, LVEF remained higher in the study group 44 ± 7% versus 26 ± 11% (P = 0.008) while Pcap did not differ. A synchronized pulsatile device decreasing systolic output from vaECMO improved LVEF and Pcap in a pig model of CA and resuscitation.
KW - Cardiac arrest
KW - —Extracorporeal membrane oxygenation
KW - —Left ventricular ejection fraction
KW - —Pulmonary capillary pressure
KW - —Synchronized pulsatile flow
UR - http://www.scopus.com/inward/record.url?scp=85043330830&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85043330830&partnerID=8YFLogxK
U2 - 10.1111/aor.13089
DO - 10.1111/aor.13089
M3 - Article
C2 - 29508418
AN - SCOPUS:85043330830
SN - 0160-564X
VL - 42
SP - 597
EP - 604
JO - Artificial Organs
JF - Artificial Organs
IS - 6
ER -