Skip to main navigation Skip to search Skip to main content

Surface roughness and preload loss of implant-supported screw retained three-unit framework fabricated by different techniques

  • Rawan Alsaif
  • , Fahim Vohra
  • , Refal Albaijan
  • , Hussain Alsayed
  • , Shahad Altuwaijri
  • , Mohammed Alrabiah

Research output: Contribution to journal › Article › peer-review

Abstract

Aim: This study evaluated the effects of selective laser melting (SLM), milling, and casting fabrication techniques on surface roughness and screw preload loss of three-unit screw-retained implant-supported Cobalt-Chromium (Co-Cr) frameworks. Methods: Ten frame-works were fabricated by each fabrication method (n = 10), and the surface roughness (Ra) was measured using a 3D optical profilometer. The frameworks were torqued to 30 Ncm, retightened after 15 minutes, and subjected to 500,000 cycles in a dual-axis chewing simulator. Pre- and post-load reverse torque values (RTV) were recorded for molar and premolar, and the reverse torque difference (RTD) was calculated. Data were analyzed using ANOVA and Tukey-Kramer tests (α = 0.01). Correlation analyses were performed to determine any relation between surface roughness and preload (RTV and RTD) across all groups. Results: Significant differences were found in surface roughness and preload loss among groups (p < 0.01). In molars, the milled group showed the lowest Ra (0.30 µm) and highest post-load RTV (25.2 Ncm), followed by the SLM group (1.73 µm, 20.2 Ncm) and cast group (1.65 µm, 16.9 Ncm). In premolars, the milled group again showed the lowest Ra (0.24 µm) and highest RTV (25.2 Ncm), followed by the SLM group (1.66 µm, 19.4 Ncm) and the cast group (2.57 µm, 17.4 Ncm). There was no significant correlation between roughness and preload loss. Conclusion: Different manufacturing technique significantly affects surface topography and screw preload. Milled frameworks showed the least surface roughness and the most torque stability.

Original languageEnglish (US)
Article number1763096
JournalFrontiers in Materials
Volume13
DOIs
StatePublished - 2026

Bibliographical note

Publisher Copyright:
Copyright © 2026 Alsaif, Vohra, Albaijan, Alsayed, Altuwaijri and Alrabiah.

Keywords

  • 3D printing
  • CAD-CAM
  • additive manufacturing
  • implant abutments
  • selective laser melting

Fingerprint

Dive into the research topics of 'Surface roughness and preload loss of implant-supported screw retained three-unit framework fabricated by different techniques'. Together they form a unique fingerprint.

Cite this