Successful implantable cardioverter-defibrillator implantation through a communicating branch of the persistent left superior vena cava

Vineet Kumar, Naoki Yoshida, Takumi Yamada

Research output: Contribution to journalArticlepeer-review

6 Scopus citations

Abstract

A left pectoral dual chamber implantable cardioverter-defibrillator (ICD) was successfully implanted through a small branch communicating between a persistent left superior vena cava (PLSVC) and right-sided venous drainage with long sheaths. Postprocedural computed tomography identified the communicating branch. ICD lead implantation through a PLSVC is challenging and sometimes unsuccessful. This case illustrates an alternative approach for ICD lead implantation in patients with a PLSVC. A PLSVC system should be carefully inspected for any communicating branches that can be utilized for lead implantation in order to increase the chance of success and minimize the risk of complications.

Original languageEnglish (US)
Pages (from-to)331-332
Number of pages2
JournalJournal of Arrhythmia
Volume31
Issue number5
DOIs
StatePublished - 2015
Externally publishedYes

Bibliographical note

Publisher Copyright:
© 2015 Japanese Heart Rhythm Society. Published by Elsevier B.V. All rights reserved.

Keywords

  • Communicating branch
  • Implantable cardioverter-defibrillator
  • Persistent left superior vena cava

Fingerprint

Dive into the research topics of 'Successful implantable cardioverter-defibrillator implantation through a communicating branch of the persistent left superior vena cava'. Together they form a unique fingerprint.