T1 - Standardization of Urine Albumin Measurements
T2 - Status and Performance Goals
AU - Miller, W. Greg
AU - Seegmiller, Jesse C.
AU - Lieske, John C.
AU - Narva, Andrew S.
AU - Bachmann, Lorin M.
N1 - Publisher Copyright:
© 2017 American Association for Clinical Chemistry.
PY - 2017/11/1
Y1 - 2017/11/1
N2 - Background: Urine albumin is a key laboratory test used for classification, assessment of risk, and monitoring treatment of patients with chronic kidney disease. Urine albumin measurement results are not standardized among different measurement procedures. Consequently, clinical guidelines using fixed decision values for urine albumin cannot be applied consistently. Content: Isotope dilution mass spectrometry reference measurement procedures and certified reference materials are being developed to enable standardization of immunoassay measurement procedures for urine albumin. A previous report determined calibration bias was the major error source for differences in results among different measurement procedures for urine albumin. Performance goals for between-day precision, ≤6% CV above 15 mg/L, and for specimen-specific effects, ≤6% CV, were established on the basis of the performance capability of current measurement procedures. The biological variation model was used to estimate a total allowable error of ≤24%-30% and from that the goal for bias of ≤7%-13%. Summary: A reference system of higher-order certified reference materials and reference measurement procedures is being developed to enable standardization of urine albumin measurement results. Goals have been established for total allowable error, specimen-specific effects, imprecision, and bias to facilitate efforts to standardize urine albumin measurement results.
AB - Background: Urine albumin is a key laboratory test used for classification, assessment of risk, and monitoring treatment of patients with chronic kidney disease. Urine albumin measurement results are not standardized among different measurement procedures. Consequently, clinical guidelines using fixed decision values for urine albumin cannot be applied consistently. Content: Isotope dilution mass spectrometry reference measurement procedures and certified reference materials are being developed to enable standardization of immunoassay measurement procedures for urine albumin. A previous report determined calibration bias was the major error source for differences in results among different measurement procedures for urine albumin. Performance goals for between-day precision, ≤6% CV above 15 mg/L, and for specimen-specific effects, ≤6% CV, were established on the basis of the performance capability of current measurement procedures. The biological variation model was used to estimate a total allowable error of ≤24%-30% and from that the goal for bias of ≤7%-13%. Summary: A reference system of higher-order certified reference materials and reference measurement procedures is being developed to enable standardization of urine albumin measurement results. Goals have been established for total allowable error, specimen-specific effects, imprecision, and bias to facilitate efforts to standardize urine albumin measurement results.
UR - http://www.scopus.com/inward/record.url?scp=85048191122&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85048191122&partnerID=8YFLogxK
U2 - 10.1373/jalm.2017.023614
DO - 10.1373/jalm.2017.023614
M3 - Review article
C2 - 33636850
AN - SCOPUS:85048191122
SN - 2576-9456
VL - 2
SP - 423
EP - 429
JO - The journal of applied laboratory medicine
JF - The journal of applied laboratory medicine
IS - 3
ER -