Stability of haemoglobin A1c (HbA1c) measurements from frozen whole blood samples stored for over a decade

Elizabeth Selvin, J. Coresh, J. Jordahl, L. Boland, Michael W Steffes

Research output: Contribution to journalArticle

41 Citations (Scopus)

Abstract

Objective: Haemoglobin A1c (HbA1c), a measure of long-term glycaemic control, is at the centre of the clinical management of diabetes mellitus. However, the reproducibility of HbA1c measurements from whole blood samples which have been in long-term storage is unknown. We undertook this study to assess the reproducibility of HbA1c measurements from whole blood samples that had been in storage at -70°C for over a decade. Research design and methods: Three hundred and thirty-six samples of frozen whole blood from the Atherosclerosis Risk in Communities (ARIC) Study, stored at -70°C for 11-14 years assayed for HbA1c using a dedicated ion-exchange HPLC assay (Tosoh A1c 2.2 Plus HPLC) were compared with measurements on these same samples conducted prior to storage (in 1990-92) using a Diamat (Bio-Rad) HPLC instrument. Results: HbA1c measurements from long-term stored samples were strongly correlated with values obtained prior to long-term storage (r = 0.97). The difference between HbA 1c from long- and short-term stored samples had a mean of 0.35% HbA1c (SD = 0.35) and a CV of 5.8%, which was approximately three times that of duplicate assays (CV 1.3 to 2.5%). Conclusions: These data demonstrate that highly correlated but more variable and slightly higher HbA1c results were obtained from frozen whole blood samples that have been in storage for more than a decade. This highly reproducible assay performance would lead to comparable ranking of individuals and unbiased estimates of relative risks and odds ratios in epidemiological studies (case-control and cohort designs), but results should be realigned when the absolute value is of interest. These results have important implications for epidemiological studies and clinical trials which have stored whole blood specimens.

Original languageEnglish (US)
Pages (from-to)1726-1730
Number of pages5
JournalDiabetic Medicine
Volume22
Issue number12
DOIs
StatePublished - Dec 1 2005

Fingerprint

Hemoglobins
Odds Ratio
High Pressure Liquid Chromatography
Epidemiologic Studies
Ion Exchange
Atherosclerosis
Diabetes Mellitus
Research Design
Clinical Trials

Keywords

  • Diabetes
  • HbA
  • Long-term storage
  • Reliability
  • Stored whole blood

Cite this

Stability of haemoglobin A1c (HbA1c) measurements from frozen whole blood samples stored for over a decade. / Selvin, Elizabeth; Coresh, J.; Jordahl, J.; Boland, L.; Steffes, Michael W.

In: Diabetic Medicine, Vol. 22, No. 12, 01.12.2005, p. 1726-1730.

Research output: Contribution to journalArticle

Selvin, Elizabeth ; Coresh, J. ; Jordahl, J. ; Boland, L. ; Steffes, Michael W. / Stability of haemoglobin A1c (HbA1c) measurements from frozen whole blood samples stored for over a decade. In: Diabetic Medicine. 2005 ; Vol. 22, No. 12. pp. 1726-1730.
@article{3097b8ec3cfa4e1cabb6c4960286131e,
title = "Stability of haemoglobin A1c (HbA1c) measurements from frozen whole blood samples stored for over a decade",
abstract = "Objective: Haemoglobin A1c (HbA1c), a measure of long-term glycaemic control, is at the centre of the clinical management of diabetes mellitus. However, the reproducibility of HbA1c measurements from whole blood samples which have been in long-term storage is unknown. We undertook this study to assess the reproducibility of HbA1c measurements from whole blood samples that had been in storage at -70°C for over a decade. Research design and methods: Three hundred and thirty-six samples of frozen whole blood from the Atherosclerosis Risk in Communities (ARIC) Study, stored at -70°C for 11-14 years assayed for HbA1c using a dedicated ion-exchange HPLC assay (Tosoh A1c 2.2 Plus HPLC) were compared with measurements on these same samples conducted prior to storage (in 1990-92) using a Diamat (Bio-Rad) HPLC instrument. Results: HbA1c measurements from long-term stored samples were strongly correlated with values obtained prior to long-term storage (r = 0.97). The difference between HbA 1c from long- and short-term stored samples had a mean of 0.35{\%} HbA1c (SD = 0.35) and a CV of 5.8{\%}, which was approximately three times that of duplicate assays (CV 1.3 to 2.5{\%}). Conclusions: These data demonstrate that highly correlated but more variable and slightly higher HbA1c results were obtained from frozen whole blood samples that have been in storage for more than a decade. This highly reproducible assay performance would lead to comparable ranking of individuals and unbiased estimates of relative risks and odds ratios in epidemiological studies (case-control and cohort designs), but results should be realigned when the absolute value is of interest. These results have important implications for epidemiological studies and clinical trials which have stored whole blood specimens.",
keywords = "Diabetes, HbA, Long-term storage, Reliability, Stored whole blood",
author = "Elizabeth Selvin and J. Coresh and J. Jordahl and L. Boland and Steffes, {Michael W}",
year = "2005",
month = "12",
day = "1",
doi = "10.1111/j.1464-5491.2005.01705.x",
language = "English (US)",
volume = "22",
pages = "1726--1730",
journal = "Diabetic Medicine",
issn = "0742-3071",
publisher = "Wiley-Blackwell",
number = "12",

}

TY - JOUR

T1 - Stability of haemoglobin A1c (HbA1c) measurements from frozen whole blood samples stored for over a decade

AU - Selvin, Elizabeth

AU - Coresh, J.

AU - Jordahl, J.

AU - Boland, L.

AU - Steffes, Michael W

PY - 2005/12/1

Y1 - 2005/12/1

N2 - Objective: Haemoglobin A1c (HbA1c), a measure of long-term glycaemic control, is at the centre of the clinical management of diabetes mellitus. However, the reproducibility of HbA1c measurements from whole blood samples which have been in long-term storage is unknown. We undertook this study to assess the reproducibility of HbA1c measurements from whole blood samples that had been in storage at -70°C for over a decade. Research design and methods: Three hundred and thirty-six samples of frozen whole blood from the Atherosclerosis Risk in Communities (ARIC) Study, stored at -70°C for 11-14 years assayed for HbA1c using a dedicated ion-exchange HPLC assay (Tosoh A1c 2.2 Plus HPLC) were compared with measurements on these same samples conducted prior to storage (in 1990-92) using a Diamat (Bio-Rad) HPLC instrument. Results: HbA1c measurements from long-term stored samples were strongly correlated with values obtained prior to long-term storage (r = 0.97). The difference between HbA 1c from long- and short-term stored samples had a mean of 0.35% HbA1c (SD = 0.35) and a CV of 5.8%, which was approximately three times that of duplicate assays (CV 1.3 to 2.5%). Conclusions: These data demonstrate that highly correlated but more variable and slightly higher HbA1c results were obtained from frozen whole blood samples that have been in storage for more than a decade. This highly reproducible assay performance would lead to comparable ranking of individuals and unbiased estimates of relative risks and odds ratios in epidemiological studies (case-control and cohort designs), but results should be realigned when the absolute value is of interest. These results have important implications for epidemiological studies and clinical trials which have stored whole blood specimens.

AB - Objective: Haemoglobin A1c (HbA1c), a measure of long-term glycaemic control, is at the centre of the clinical management of diabetes mellitus. However, the reproducibility of HbA1c measurements from whole blood samples which have been in long-term storage is unknown. We undertook this study to assess the reproducibility of HbA1c measurements from whole blood samples that had been in storage at -70°C for over a decade. Research design and methods: Three hundred and thirty-six samples of frozen whole blood from the Atherosclerosis Risk in Communities (ARIC) Study, stored at -70°C for 11-14 years assayed for HbA1c using a dedicated ion-exchange HPLC assay (Tosoh A1c 2.2 Plus HPLC) were compared with measurements on these same samples conducted prior to storage (in 1990-92) using a Diamat (Bio-Rad) HPLC instrument. Results: HbA1c measurements from long-term stored samples were strongly correlated with values obtained prior to long-term storage (r = 0.97). The difference between HbA 1c from long- and short-term stored samples had a mean of 0.35% HbA1c (SD = 0.35) and a CV of 5.8%, which was approximately three times that of duplicate assays (CV 1.3 to 2.5%). Conclusions: These data demonstrate that highly correlated but more variable and slightly higher HbA1c results were obtained from frozen whole blood samples that have been in storage for more than a decade. This highly reproducible assay performance would lead to comparable ranking of individuals and unbiased estimates of relative risks and odds ratios in epidemiological studies (case-control and cohort designs), but results should be realigned when the absolute value is of interest. These results have important implications for epidemiological studies and clinical trials which have stored whole blood specimens.

KW - Diabetes

KW - HbA

KW - Long-term storage

KW - Reliability

KW - Stored whole blood

UR - http://www.scopus.com/inward/record.url?scp=27744608233&partnerID=8YFLogxK