TY - JOUR
T1 - Solid-phase extraction and simultaneous spectrophotometric determination of trace amounts of Co, Ni and Cu using partial least squares regression
AU - Hejazi, Leila
AU - Mohammadi, Diako E.
AU - Yamini, Yadollah
AU - Brereton, Richard G.
N1 - Copyright:
Copyright 2018 Elsevier B.V., All rights reserved.
PY - 2004/1/9
Y1 - 2004/1/9
N2 - A novel sensitive and simple method for rapid extraction, preconcentration and determination of cobalt, nickel and copper as their 1-(2-pyridilazo)-2- naphthol (PAN) complexes using polytetrafluoroethylene filter as solid phase and multivariate calibration of spectrophotometric data is presented. The analytical wavelengths of 400-700nm were chosen and the experimental calibration matrix for partial least squares (PLS) was designed with 21 samples of 5.90-41.25, 0.30-29.35 and 0.64-41.30ngml-1 for cobalt, nickel and copper, respectively. The cross-validation method was used for selecting the number of components. The root-mean-square errors of predictions (RMSEPs) were between 0.48 and 1.37ngml-1. In this work we could reach preconcentration factors of 100 or even higher by using polytetrafluoroethylene as solid phase which is cheap and can be used in a wide range of pH, flow rates and for many times. The proposed method was successfully applied to the simultaneous determination of Co, Ni and Cu in tap and pit water samples.
AB - A novel sensitive and simple method for rapid extraction, preconcentration and determination of cobalt, nickel and copper as their 1-(2-pyridilazo)-2- naphthol (PAN) complexes using polytetrafluoroethylene filter as solid phase and multivariate calibration of spectrophotometric data is presented. The analytical wavelengths of 400-700nm were chosen and the experimental calibration matrix for partial least squares (PLS) was designed with 21 samples of 5.90-41.25, 0.30-29.35 and 0.64-41.30ngml-1 for cobalt, nickel and copper, respectively. The cross-validation method was used for selecting the number of components. The root-mean-square errors of predictions (RMSEPs) were between 0.48 and 1.37ngml-1. In this work we could reach preconcentration factors of 100 or even higher by using polytetrafluoroethylene as solid phase which is cheap and can be used in a wide range of pH, flow rates and for many times. The proposed method was successfully applied to the simultaneous determination of Co, Ni and Cu in tap and pit water samples.
KW - Multivariate calibration
KW - PAN
KW - Solid phase extraction
KW - Spectrophotometry
UR - http://www.scopus.com/inward/record.url?scp=1042302183&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=1042302183&partnerID=8YFLogxK
U2 - 10.1016/S0039-9140(03)00412-0
DO - 10.1016/S0039-9140(03)00412-0
M3 - Article
C2 - 18969279
AN - SCOPUS:1042302183
SN - 0039-9140
VL - 62
SP - 183
EP - 189
JO - Talanta
JF - Talanta
IS - 1
ER -