Abstract
Line-of-sight tunable-diode-laser absorption spectroscopy (LOS-TDLAS) with multiple absorption lines is introduced for non-uniform temperature measurement. Temperature binning method combined with Gauss-Seidel iteration method is used to measure temperature probability distribution function (PDF) along the line-of-sight (LOS). Through 100 simulated measurements, the variation of measurement accuracy is investigated with the number of absorption lines, the number of temperature bins and the magnitude of temperature non-uniformity. A field model with 2-T temperature distribution and 15 well-selected absorption lines are used for the simulation study. The Gauss-Seidel iteration method is discussed for its reliability. The investigation result about the variation of measurement accuracy with the number of temperature bins is different from the previous research results.
| Original language | English (US) |
|---|---|
| Article number | 124207 |
| Journal | Chinese Physics B |
| Volume | 23 |
| Issue number | 12 |
| DOIs | |
| State | Published - Dec 1 2014 |
| Externally published | Yes |
Bibliographical note
Publisher Copyright:© 2014 Chinese Physical Society and IOP Publishing Ltd.
Keywords
- Gauss-Seidel iteration method
- Simulation
- TDLAS
- Temperature non-uniformity