TY - JOUR
T1 - Signal-to-noise ratio and spectral linewidth improvements between 1.5 and 7 tesla in proton echo-planar spectroscopic imaging
AU - Otazo, Ricardo
AU - Mueller, Bryon
AU - Ugurbil, Kamil
AU - Wald, Lawrence
AU - Posse, Stefan
PY - 2006/12
Y1 - 2006/12
N2 - This study characterizes gains in sensitivity and spectral resolution of proton echo-planar spectroscopic imaging (PEPSI) with increasing magnetic field strength (B0). Signal-to-noise ratio (SNR) per unit volume and unit time, and intrinsic linewidth (LW) of N-acetyl-aspartate (NAA), creatine (Cr), and choline (Cho) were measured with PEPSI at 1.5, 3, 4, and 7 Tesla on scanners that shared a similar software and hardware platform, using circularly polarized (CP) and eight-channel phased-array (PA) head coils. Data were corrected for relaxation effects and processed with a time-domain matched filter (MF) adapted to each B0. The SNR and LW measured with PEPSI were very similar to those measured with conventional point-resolved spectroscopy (PRESS) SI. Measurements with the CP coil demonstrated a nearly linear SNR gain with respect to B0 in central brain regions. For the PA coil, the SNR-B0 relationship was less than linear, but there was a substantial SNR increase in comparison to the CP coil. The LW in units of ppm decreased with B0, resulting in improved spectral resolution. These studies using PEPSI demonstrated linear gains in SNR with respect to B0, consistent with theoretical expectations, and a decrease in ppm LW with increasing B0.
AB - This study characterizes gains in sensitivity and spectral resolution of proton echo-planar spectroscopic imaging (PEPSI) with increasing magnetic field strength (B0). Signal-to-noise ratio (SNR) per unit volume and unit time, and intrinsic linewidth (LW) of N-acetyl-aspartate (NAA), creatine (Cr), and choline (Cho) were measured with PEPSI at 1.5, 3, 4, and 7 Tesla on scanners that shared a similar software and hardware platform, using circularly polarized (CP) and eight-channel phased-array (PA) head coils. Data were corrected for relaxation effects and processed with a time-domain matched filter (MF) adapted to each B0. The SNR and LW measured with PEPSI were very similar to those measured with conventional point-resolved spectroscopy (PRESS) SI. Measurements with the CP coil demonstrated a nearly linear SNR gain with respect to B0 in central brain regions. For the PA coil, the SNR-B0 relationship was less than linear, but there was a substantial SNR increase in comparison to the CP coil. The LW in units of ppm decreased with B0, resulting in improved spectral resolution. These studies using PEPSI demonstrated linear gains in SNR with respect to B0, consistent with theoretical expectations, and a decrease in ppm LW with increasing B0.
KW - High field
KW - Linewidth
KW - Magnetic resonance
KW - Signal-to-noise ratio
KW - Spectroscopic imaging
UR - http://www.scopus.com/inward/record.url?scp=33845239492&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33845239492&partnerID=8YFLogxK
U2 - 10.1002/mrm.21067
DO - 10.1002/mrm.21067
M3 - Article
C2 - 17094090
AN - SCOPUS:33845239492
SN - 0740-3194
VL - 56
SP - 1200
EP - 1210
JO - Magnetic resonance in medicine
JF - Magnetic resonance in medicine
IS - 6
ER -