TY - JOUR
T1 - Short term outcomes of GreenLight vapor incision technique (VIT) of the prostate
T2 - Comparison of outcomes to standard GreenLight 120W HPS vaporization in prostate volumes greater than 80 cc
AU - Ben-Zvi, Tal
AU - Hueber, Pierre Alain
AU - Abdollah, Firas
AU - Liberman, Daniel
AU - Bhojani, Naeem
AU - Gautam, Gagan
AU - Zorn, Kevin C.
N1 - Copyright:
Copyright 2013 Elsevier B.V., All rights reserved.
PY - 2013
Y1 - 2013
N2 - Introduction: To evaluate a hybrid technique involving GreenLight 120W HPS vapor incision tissue removal in prostate glands > 80 cc. Materials and methods: Vapor incision technique (VIT) was performed in 25 consecutive men with a prostate > 80 cc by a single surgeon from May 2010 until September 2010. VIT involved adenoma incisions at 5 and 7-o'clock positions followed by 3, 9 and 12 o'clock down to the surgical capsule. Side-fire vaporization along the capsule excised transurethral resection of the prostate (TURP) like tissue strips for later retrieval. Functional evaluations were performed at 1 and 3 months. Outcomes and complications were compared retrospectively to baseline and a size matched- cohort of 25 men who previously underwent standard vaporization-only photoselective vaporization prostatectomy (PVP). Results: The VIT and control subgroups were comparable. Mean laser time, operative time and energy usage were reduced in the VIT group compared to controls (35 min versus 48 min; 63 min versus 80 min; and 227 k versus 325 kJ respectively; all p < 0.05). At 3 months the VIT subgroup demonstrated improved Qmax and post void residual (PVR) (197% versus 173%, 88% versus 72%; all p < 0.05) compared to control. VIT showed a 68% reduction in mean preoperative PSA at 3 months compared to 50% for the control group (p<0.01). Hospital stay, catheterization time and complication rates were comparable. Conclusions: Our data demonstrates that VIT provides superior short term outcomes to standard HPS-PVP in men with prostate volumes > 80 cc. VIT appears to be more time-efficient, consumes less energy and obtains tissue for pathological evaluation. Further follow up is required to assess the durability of GreenLight HPS-VIT to PVP vaporization-only for large prostate glands.
AB - Introduction: To evaluate a hybrid technique involving GreenLight 120W HPS vapor incision tissue removal in prostate glands > 80 cc. Materials and methods: Vapor incision technique (VIT) was performed in 25 consecutive men with a prostate > 80 cc by a single surgeon from May 2010 until September 2010. VIT involved adenoma incisions at 5 and 7-o'clock positions followed by 3, 9 and 12 o'clock down to the surgical capsule. Side-fire vaporization along the capsule excised transurethral resection of the prostate (TURP) like tissue strips for later retrieval. Functional evaluations were performed at 1 and 3 months. Outcomes and complications were compared retrospectively to baseline and a size matched- cohort of 25 men who previously underwent standard vaporization-only photoselective vaporization prostatectomy (PVP). Results: The VIT and control subgroups were comparable. Mean laser time, operative time and energy usage were reduced in the VIT group compared to controls (35 min versus 48 min; 63 min versus 80 min; and 227 k versus 325 kJ respectively; all p < 0.05). At 3 months the VIT subgroup demonstrated improved Qmax and post void residual (PVR) (197% versus 173%, 88% versus 72%; all p < 0.05) compared to control. VIT showed a 68% reduction in mean preoperative PSA at 3 months compared to 50% for the control group (p<0.01). Hospital stay, catheterization time and complication rates were comparable. Conclusions: Our data demonstrates that VIT provides superior short term outcomes to standard HPS-PVP in men with prostate volumes > 80 cc. VIT appears to be more time-efficient, consumes less energy and obtains tissue for pathological evaluation. Further follow up is required to assess the durability of GreenLight HPS-VIT to PVP vaporization-only for large prostate glands.
KW - Benign prostatic hyperplasia
KW - GreenLight 120W HPS
KW - Laser photoselective vaporization
KW - Prostate size
UR - http://www.scopus.com/inward/record.url?scp=84884804959&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84884804959&partnerID=8YFLogxK
M3 - Article
C2 - 23433136
AN - SCOPUS:84884804959
SN - 1195-9479
VL - 20
SP - 6633
EP - 6639
JO - Canadian Journal of Urology
JF - Canadian Journal of Urology
IS - 1
ER -