Abstract
Within-person and methodological variability of a given analyte are important elements in determining whether an individual has altered concentrations of that analyte. We report the short-term (1 month) within- person, between-person, and methodological variability of plasma homocysteine in 20 healthy participants from whom samples were drawn weekly for 4 weeks. The short-term between-person variance was high, whereas within-person and methodological variances were relatively very low, giving a high reliability coefficient (R) for homocysteine (R = 0.94). The long-term (30 months) reliability coefficient was 0.65, but was greatly influenced by an outlier (R = 0.82 with the outlier excluded). The data suggest that an individual's plasma homocysteine concentration is relatively constant over at least 1 month, and a single measurement characterizes the average concentration reasonably well.
Original language | English (US) |
---|---|
Pages (from-to) | 141-145 |
Number of pages | 5 |
Journal | Clinical chemistry |
Volume | 43 |
Issue number | 1 |
DOIs | |
State | Published - 1997 |
Keywords
- cardiovascular diseases
- hyperhomocysteinemia
- reliability coefficient
- variation, source of