Abstract
Steel columns are commonly attached to concrete foundations with groups of cast-in-place headed anchors. Recent physical tests and simulations have shown that the strength of these connections can be limited by concrete breakout failure. Four full-scale physical specimens of axially loaded columns attached to a foundation slab were tested, varying the shear reinforcement configuration in the slab. All specimens were governed by concrete breakout failure. The tests suggest that adequately placed distributed shear reinforcement can increase connection strength and displacement capacity. Steep cone failures were observed to limit the beneficial effect of shear reinforcement. Calibrated finite element models were used to investigate critical parameters such as the extent of the shear-reinforced region and bar spacing. A design approach is proposed to calculate connection strength by adding the strength of the concrete and the distributed shear reinforcement. Design detailing is discussed.
| Original language | English (US) |
|---|---|
| Pages (from-to) | 169-181 |
| Number of pages | 13 |
| Journal | ACI Structural Journal |
| Volume | 122 |
| Issue number | 6 |
| DOIs | |
| State | Published - Nov 1 2025 |
Bibliographical note
Publisher Copyright:© 2025, American Concrete Institute. All rights reserved.
Keywords
- anchor reinforcement
- anchoring to concrete
- concrete breakout
- foundations
- shear reinforcement
- supplementary reinforcement
Fingerprint
Dive into the research topics of 'Shear-Reinforced Concrete Breakout Failure in TensionLoaded Anchor Groups'. Together they form a unique fingerprint.Cite this
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS