TY - JOUR
T1 - Self-assembled graphene and copper nanoparticles composite sensor for nitrate determination
AU - Wang, Li
AU - Kim, Jungyoon
AU - Cui, Tianhong
N1 - Publisher Copyright:
© 2018, Springer-Verlag GmbH Germany, part of Springer Nature.
PY - 2018/9/1
Y1 - 2018/9/1
N2 - A new sensor based on decorated copper nanoparticles and self-assembled graphene was fabricated and exemplified with the determination of nitrate solutions. Traditionally, graphene is coated on the sensor by drop-casting, leading to poor adhesion between graphene and the sensor. The self-assembled graphene proposed in this paper not only have a firm connection with the substrate, but also provide a three-dimensional network structure for copper nanoparticles. Copper was found as an effective catalyst for nitrate reduction. The combination of copper nanoparticles and self-assembled graphene can greatly enhance the sensitivity. Thus, low detection limit of 7.89 µM is obtained for nitrate, which to our knowledge, is among the lowest reported in the literatures. This method was employed for the determination of nitrate in lake water and the results were in good agreement with those obtained from a standard analytical procedure.
AB - A new sensor based on decorated copper nanoparticles and self-assembled graphene was fabricated and exemplified with the determination of nitrate solutions. Traditionally, graphene is coated on the sensor by drop-casting, leading to poor adhesion between graphene and the sensor. The self-assembled graphene proposed in this paper not only have a firm connection with the substrate, but also provide a three-dimensional network structure for copper nanoparticles. Copper was found as an effective catalyst for nitrate reduction. The combination of copper nanoparticles and self-assembled graphene can greatly enhance the sensitivity. Thus, low detection limit of 7.89 µM is obtained for nitrate, which to our knowledge, is among the lowest reported in the literatures. This method was employed for the determination of nitrate in lake water and the results were in good agreement with those obtained from a standard analytical procedure.
UR - http://www.scopus.com/inward/record.url?scp=85042076110&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85042076110&partnerID=8YFLogxK
U2 - 10.1007/s00542-018-3792-7
DO - 10.1007/s00542-018-3792-7
M3 - Article
AN - SCOPUS:85042076110
SN - 0946-7076
VL - 24
SP - 3623
EP - 3630
JO - Microsystem Technologies
JF - Microsystem Technologies
IS - 9
ER -