The problem of selection of motors in thyristorized dc drives is considered, taking into account changes in ventilation and in the coefficient of utilization of the motors when speed is changed. The proposed graph and analytical method of calculation is simple. It ensures sufficiently high precision and clarity.
| Translated title of the contribution | Selection of the Capacity of Motors in Thyristorized DC Electric Drive. |
|---|---|
| Original language | Russian |
| Pages (from-to) | 1-5 |
| Number of pages | 5 |
| Journal | Elektrotekhnika |
| Issue number | 6 |
| State | Published - 1974 |