TY - JOUR
T1 - Safety and Feasibility of Balloon-Assisted Embolization with Onyx of Brain Arteriovenous Malformations Revisited
T2 - Personal Experience with the Scepter XC Balloon Microcatheter
AU - Jagadeesan, Bharathi D.
AU - Grande, Andrew W.
AU - Tummala, Ramachandra P.
N1 - Publisher Copyright:
© 2018 S. Karger AG, Basel. Copyright: All rights reserved.
PY - 2018/10/1
Y1 - 2018/10/1
N2 - Background/Objective: Compliant dual-lumen balloon microcatheters have been used to perform balloon-assisted embolization (BAE) of brain arteriovenous malformations (AVMs) with ethylene vinyl alcohol copolymer (Onyx). However, vessel rupture and microcatheter retention have been reported from BAE using these microcatheters. Using an extra-compliant balloon microcatheter (Scepter XC; Microvention, Tustin, CA, USA) could help avoid pial vessel rupture during BAE. We herein report our experience using this balloon microcatheter for BAE. Methods: This retrospective study included patients who underwent BAE of brain AVMs at our institution between June 2012 and March 2017. Results: The extra-compliant Scepter XC balloon microcatheter was used for BAE of brain AVMs in 23 patients aged 44.3 ± 16.7 years (range 0-65 years). A total of 40 intracranial vessels (39 pial arteries and 1 pial vein) were catheterized and embolized during 30 separate sessions. In all instances, the balloon microcatheter could be successfully advanced to the AVM nidus. A mean volume of 2.4 ± 1.7 mL (range 0.65-4.6 mL) of Onyx was injected per session. There were no instances of vessel rupture, microcatheter retention, or stroke. Conclusion: Utilization of the extra-compliant balloon microcatheter results in safe and effective BAE, which adds to the growing experience with BAE for AVM treatment.
AB - Background/Objective: Compliant dual-lumen balloon microcatheters have been used to perform balloon-assisted embolization (BAE) of brain arteriovenous malformations (AVMs) with ethylene vinyl alcohol copolymer (Onyx). However, vessel rupture and microcatheter retention have been reported from BAE using these microcatheters. Using an extra-compliant balloon microcatheter (Scepter XC; Microvention, Tustin, CA, USA) could help avoid pial vessel rupture during BAE. We herein report our experience using this balloon microcatheter for BAE. Methods: This retrospective study included patients who underwent BAE of brain AVMs at our institution between June 2012 and March 2017. Results: The extra-compliant Scepter XC balloon microcatheter was used for BAE of brain AVMs in 23 patients aged 44.3 ± 16.7 years (range 0-65 years). A total of 40 intracranial vessels (39 pial arteries and 1 pial vein) were catheterized and embolized during 30 separate sessions. In all instances, the balloon microcatheter could be successfully advanced to the AVM nidus. A mean volume of 2.4 ± 1.7 mL (range 0.65-4.6 mL) of Onyx was injected per session. There were no instances of vessel rupture, microcatheter retention, or stroke. Conclusion: Utilization of the extra-compliant balloon microcatheter results in safe and effective BAE, which adds to the growing experience with BAE for AVM treatment.
UR - http://www.scopus.com/inward/record.url?scp=85051078145&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85051078145&partnerID=8YFLogxK
U2 - 10.1159/000490579
DO - 10.1159/000490579
M3 - Article
C2 - 30410522
AN - SCOPUS:85051078145
SN - 1664-9737
VL - 7
SP - 439
EP - 444
JO - Interventional Neurology
JF - Interventional Neurology
IS - 6
ER -