Skip to main navigation Skip to search Skip to main content

Right Ventricular Outflow Tract Reconstruction With a Polytetrafluoroethylene Monocusp Valve: A 20-Year Experience

  • Mohineesh Kumar
  • , Mark W. Turrentine
  • , Mark D. Rodefeld
  • , Teresa Bell
  • , John W. Brown

Research output: Contribution to journalArticlepeer-review

Abstract

In patients with tetralogy of Fallot (TOF), pulmonary atresia (PA), and other congenital right ventricular outflow tract (RVOT) malformations, polytetrafluoroethylene (PTFE) monocusp outflow tract patches (MOTP) relieve obstruction and provide pulmonary valve competence. The purpose of this study was to determine whether our PTFE-MOTP was an acceptable short- and mid-term remedy for patients with TOF or PA as assessed by freedom from severe pulmonary regurgitation and freedom from reoperation. From 1994-2014, 171 patients (mean age 1.5 ± 1.5 years; median 1.1 years) with TOF or PA underwent initial right ventricular outflow tract (RVOT) reconstruction with a PTFE-MOTP. Patients were studied intraoperatively and serially postoperatively using echocardiography and cardiac magnetic resonance imaging (CMR) to determine pulmonary valve dysfunction defined as a peak gradient >40 mm Hg or valve regurgitation>moderate. The mean follow-up duration was 10.9 ± 5.8 years (range: 1 month-20 years). There were 5 late deaths and 1 early death. There was a significant difference between the preoperative and postoperative peak RVOT gradients (74.0 vs 25.2 mm Hg). Of the 171 patients, 25 were lost to follow-up, and 42 have required replacement of their monocusp valves 10.1 ± 5.0 years (range: 5 months-19 years) after original monocusp insertion. At 10-year follow-up, severe pulmonary regurgitation was seen in less than 25% of patients, and severe pulmonary stenosis was seen in less than 10% of patients. Since 2007, CMR was used in 44 patients to characterize cardiac function in patients under consideration for PTFE-MOTP replacement. The average right ventricular-to-left ventricular (RV/LV) ratio on CMR was 1.7 ± 0.5 in these patients. CMR also showed that RV ejection fraction (52 ± 9%) and left ventricular ejection fraction (58 ± 7%) were both preserved in most patients. The PTFE-MOTP is an excellent short-term and mid-term option for initial RVOT reconstruction, particularly in children with TOF with nonsalvageable pulmonary valve or PA-ventricular septal defect.

Original languageEnglish (US)
Pages (from-to)463-470
Number of pages8
JournalSeminars in thoracic and cardiovascular surgery
Volume28
Issue number2
DOIs
StatePublished - Feb 2 2016
Externally publishedYes

Bibliographical note

Publisher Copyright:
© 2016 Elsevier Inc.

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Gore-tex Monocusp
  • Left-Systole
  • Right-Diastole

Fingerprint

Dive into the research topics of 'Right Ventricular Outflow Tract Reconstruction With a Polytetrafluoroethylene Monocusp Valve: A 20-Year Experience'. Together they form a unique fingerprint.

Cite this