Skip to main navigation Skip to search Skip to main content

Proton-free induction decay MRSI at 7 T in the human brain using an egg-shaped modified rosette K-space trajectory

  • Simon Blömer
  • , Lukas Hingerl
  • , Małgorzata Marjańska
  • , Wolfgang Bogner
  • , Stanislav Motyka
  • , Gilbert Hangel
  • , Antoine Klauser
  • , Ovidiu C. Andronesi
  • , Bernhard Strasser

Research output: Contribution to journal › Article › peer-review

Abstract

Purpose: Proton (1H)-MRSI via spatial-spectral encoding poses high demands on gradient hardware at ultra-high fields and high-resolutions. Rosette trajectories help alleviate these problems, but at reduced SNR-efficiency because of their k-space densities not matching any desired k-space filter. We propose modified rosette trajectories, which more closely match a Hamming filter, and thereby improve SNR performance while still staying within gradient hardware limitations and without prolonging scan time. Methods: Analytical and synthetic simulations were validated with phantom and in vivo measurements at 7 T. The rosette and modified rosette trajectories were measured in five healthy volunteers in 6 min in a 2D slice in the brain. An elliptical phase-encoding sequence was measured in one volunteer in 22 min, and a 3D sequence was measured in one volunteer within 19 min. The SNR per-unit-time, linewidth, Cramer-Rao lower bounds (CRLBs), lipid contamination, and data quality of the proposed modified rosette trajectory were compared to the rosette trajectory. Results: Using the modified rosette trajectories, an improved k-space weighting function was achieved resulting in an SNR per-unit-time increase of up to 12% compared to rosette's and 23% compared to elliptical phase-encoding, dependent on the two additional trajectory parameters. Similar results were achieved for the theoretical SNR calculation based on k-space densities, as well as when using the pseudo-replica method for simulated, in vivo, and phantom data. The CRLBs of γ-aminobutyric acid and N-acetylaspartylglutamate improved non-significantly for the modified rosette trajectory, whereas the linewidths and lipid contamination remained similar. Conclusion: By optimizing the shape of the rosette trajectory, the modified rosette trajectories achieved higher SNR per-unit-time and enhanced data quality at the same scan time.

Original languageEnglish (US)
Pages (from-to)1443-1457
Number of pages15
JournalMagnetic resonance in medicine
Volume93
Issue number4
DOIs
StatePublished - Apr 2025

Bibliographical note

Publisher Copyright:
© 2024 The Author(s). Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.

Keywords

  • 7 T
  • SNR efficiency
  • gradient hardware restrictions
  • magnetic resonance spectroscopic imaging
  • modified rosette trajectory
  • non-Cartesian trajectory

Fingerprint

Dive into the research topics of 'Proton-free induction decay MRSI at 7 T in the human brain using an egg-shaped modified rosette K-space trajectory'. Together they form a unique fingerprint.

Cite this