TY - JOUR
T1 - Posttraumatic osteonecrosis in a swine model
T2 - Correlation of blood cell flux, MRI and histology
AU - Seiler, John Gray
AU - Kregor, Philip J.
AU - Conrad, Ernest U.
AU - Swiontkowski, Marc F.
PY - 1996
Y1 - 1996
N2 - We used a miniature swine femoral neck fracture model to demonstrate the effects of the fracture on blood flow, histologic appearance, MRI signal and the development of posttraumatic osteonecrosis. The fracture was created and internally fixed in the right hip of 11 swine, with the left hip serving as the control. Femoral head blood flow via Laser Doppler Flowmetry and MRI data was examined for the experimental hip preoperatively, postoperatively and at 1, 2, 4 and 8 weeks postfracture. At 8 weeks, the animals were killed and the femoral heads were evaluated. Femoral head blood flow decreased immediately postfracture and continued to diminish with time. MRI signal intensities in the femoral head at 4 and 8 weeks were significantly less when the fixation failed than when it was intact. Histologic grades (0-14 points) and bone densities were 7.6 and 49%, respectively, on the experimental side, compared to 1.6 and 56% on the control side. Histologic grading, bone density values and blood flow data had no relation to changes in MRI signal intensity.
AB - We used a miniature swine femoral neck fracture model to demonstrate the effects of the fracture on blood flow, histologic appearance, MRI signal and the development of posttraumatic osteonecrosis. The fracture was created and internally fixed in the right hip of 11 swine, with the left hip serving as the control. Femoral head blood flow via Laser Doppler Flowmetry and MRI data was examined for the experimental hip preoperatively, postoperatively and at 1, 2, 4 and 8 weeks postfracture. At 8 weeks, the animals were killed and the femoral heads were evaluated. Femoral head blood flow decreased immediately postfracture and continued to diminish with time. MRI signal intensities in the femoral head at 4 and 8 weeks were significantly less when the fixation failed than when it was intact. Histologic grades (0-14 points) and bone densities were 7.6 and 49%, respectively, on the experimental side, compared to 1.6 and 56% on the control side. Histologic grading, bone density values and blood flow data had no relation to changes in MRI signal intensity.
UR - http://www.scopus.com/inward/record.url?scp=0029935016&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0029935016&partnerID=8YFLogxK
U2 - 10.3109/17453679608994682
DO - 10.3109/17453679608994682
M3 - Article
C2 - 8686462
AN - SCOPUS:0029935016
SN - 1745-3674
VL - 67
SP - 249
EP - 254
JO - Acta Orthopaedica
JF - Acta Orthopaedica
IS - 3
ER -