Abstract
Wearable technologies, particularly e-textile systems, are becoming integral to rehabilitation applications, where precise placement of sensors and actuators is essential for accurate data collection and effective intervention. E-textile platforms that support repositionability of components can help alleviate the positioning error associated with hard-wired smart garments and the expense associated with custom-fit garments. However, repositionable architectures may also impose constraints on positioning. It is not known if this constraint exceeds the variability in placement accuracy between expert clinicians. This study aimed to evaluate the accuracy of component placement on an e-textile platform relative to anatomical landmarks. Eight experts participated, placing markers on landmarks such as the quadriceps, hamstrings, tibialis anterior, and calf on the body surface and on locations afforded by an e-textile garment. Marker placements were analyzed using a VICON motion analysis system to measure deviations from ideal anatomical positions. The results indicated that most anatomical positions showed no significant differences between body and garment placement across the x, y, and z axes. However, notable variations were observed in larger muscle groups like the quadriceps and hamstrings. These findings demonstrate that the positioning constraints imposed by the garment are within the tolerance for locating anatomical positions, supporting reliable data collection for biomechanical analyses in clinical contexts. This study provides valuable insights into the 3D positional accuracy of anatomical markers on the lower limbs when using e-textile systems, offering guidance for improving future iterations of wearable technology to enhance their effectiveness in clinical and rehabilitation applications.
| Original language | English (US) |
|---|---|
| Title of host publication | Proceedings of the 2025 Design of Medical Devices Conference, DMD 2025 |
| Publisher | American Society of Mechanical Engineers (ASME) |
| ISBN (Electronic) | 9780791888735 |
| DOIs | |
| State | Published - 2025 |
| Event | 2025 Design of Medical Devices Conference, DMD 2025 - Minneapolis, United States Duration: Apr 28 2025 → Apr 30 2025 |
Publication series
| Name | Proceedings of the 2025 Design of Medical Devices Conference, DMD 2025 |
|---|
Conference
| Conference | 2025 Design of Medical Devices Conference, DMD 2025 |
|---|---|
| Country/Territory | United States |
| City | Minneapolis |
| Period | 4/28/25 → 4/30/25 |
Bibliographical note
Publisher Copyright:© 2025 by ASME.
Keywords
- E-textiles
- lower-limb rehabilitation
- sensor placement
- wearable actuation
- wearable sensing
- wearable technology
Fingerprint
Dive into the research topics of 'PLUG-AND-PLAY WEARABLES: EVALUATING SENSOR PLACEMENT RESOLUTION ON GARMENT IN RELATION TO CLINICIANS' REQUIREMENTS'. Together they form a unique fingerprint.Cite this