TY - JOUR
T1 - Pitch discrimination of diotic and dichotic tone complexes
T2 - Harmonic resolvability or harmonic number?
AU - Bernstein, Joshua G.
AU - Oxenham, Andrew J.
PY - 2003/6/1
Y1 - 2003/6/1
N2 - Three experiments investigated the relationship between harmonic number, harmonic resolvability, and the perception of harmonic complexes. Complexes with successive equal-amplitude sine- or random-phase harmonic components of a 100- or 200-Hz fundamental frequency (f0) were presented dichotically, with even and odd components to opposite ears, or diotically, with all harmonics presented to both ears. Experiment 1 measured performance in discriminating a 3.5%-5% frequency difference between a component of a harmonic complex and a pure tone in isolation. Listeners achieved at least 75% correct for approximately the first 10 and 20 individual harmonics in the diotic and dichotic conditions, respectively, verifying that only processes before the binaural combination of information limit frequency selectivity. Experiment 2 measured fundamental frequency difference limens (f0 DLs) as a function of the average lowest harmonic number. Similar results at both f0's provide further evidence that harmonic number, not absolute frequency, underlies the order- of-magnitude increase observed in f0 DLs when only harmonics above about the 10th are presented. Similar results under diotic and dichotic conditions indicate that the auditory system, in performing f0 discrimination, is unable to utilize the additional peripherally resolved harmonics in the dichotic case. In experiment 3, dichotic complexes containing harmonics below the 12th, or only above the 15th, elicited pitches of the f0 and twice the f0, respectively. Together, experiments 2 and 3 suggest that harmonic number, regardless of peripheral resolvability, governs the transition between two different pitch percepts, one based on the frequencies of individual resolved harmonics and the other based on the periodicity of the temporal envelope.
AB - Three experiments investigated the relationship between harmonic number, harmonic resolvability, and the perception of harmonic complexes. Complexes with successive equal-amplitude sine- or random-phase harmonic components of a 100- or 200-Hz fundamental frequency (f0) were presented dichotically, with even and odd components to opposite ears, or diotically, with all harmonics presented to both ears. Experiment 1 measured performance in discriminating a 3.5%-5% frequency difference between a component of a harmonic complex and a pure tone in isolation. Listeners achieved at least 75% correct for approximately the first 10 and 20 individual harmonics in the diotic and dichotic conditions, respectively, verifying that only processes before the binaural combination of information limit frequency selectivity. Experiment 2 measured fundamental frequency difference limens (f0 DLs) as a function of the average lowest harmonic number. Similar results at both f0's provide further evidence that harmonic number, not absolute frequency, underlies the order- of-magnitude increase observed in f0 DLs when only harmonics above about the 10th are presented. Similar results under diotic and dichotic conditions indicate that the auditory system, in performing f0 discrimination, is unable to utilize the additional peripherally resolved harmonics in the dichotic case. In experiment 3, dichotic complexes containing harmonics below the 12th, or only above the 15th, elicited pitches of the f0 and twice the f0, respectively. Together, experiments 2 and 3 suggest that harmonic number, regardless of peripheral resolvability, governs the transition between two different pitch percepts, one based on the frequencies of individual resolved harmonics and the other based on the periodicity of the temporal envelope.
UR - http://www.scopus.com/inward/record.url?scp=0038621657&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0038621657&partnerID=8YFLogxK
U2 - 10.1121/1.1572146
DO - 10.1121/1.1572146
M3 - Article
C2 - 12822804
AN - SCOPUS:0038621657
SN - 0001-4966
VL - 113
SP - 3323
EP - 3334
JO - Journal of the Acoustical Society of America
JF - Journal of the Acoustical Society of America
IS - 6
ER -