TY - JOUR
T1 - PH-dependent equilibrium isotope fractionation associated with the compound specific nitrogen and carbon isotope analysis of substituted anilines by SPME-GC/IRMS
AU - Skarpeli-Liati, Marita
AU - Turgeon, Aurora
AU - Garr, Ashley N.
AU - Arnold, William A.
AU - Cramer, Christopher J.
AU - Hofstetter, Thomas B.
PY - 2011/3/1
Y1 - 2011/3/1
N2 - Solid-phase microextraction (SPME) coupled to gas chromatography/isotope ratio mass spectrometry (GC/IRMS) was used to elucidate the effects of N-atom protonation on the analysis of N and C isotope signatures of selected aromatic amines. Precise and accurate isotope ratios were measured using polydimethylsiloxane/divinylbenzene (PDMS/DVB) as the SPME fiber material at solution pH-values that exceeded the pKa of the substituted aniline's conjugate acid by two pH-units. Deviations of d15N and d 13C-values from reference measurements by elemental analyzer IRMS were small (<0.9%0) and within the typical uncertainties of isotope ratio measurements by SPME-GC/IRMS. Under these conditions, the detection limits for accurate isotope ratio measurements were between 0.64 and 2.1 mg L-1 for d15N and between 0.13 and 0.54 mg L -1 for d13C, respectively. Substantial inverse N isotope fractionation was observed by SPME-GC/IRMS as the fraction of protonated species increased with decreasing pH leading to deviations of -20%0 while the corresponding d13C-values were largely invariant. From isotope ratio analysis at different solution pHs and theoretical calculations by density functional theory, we derived equilibrium isotope effects, EIEs, pertinent to aromatic amine protonation of 0.980 and 1.001 for N and C, respectively, which were very similar for all compounds investigated. Our work shows that N-atom protonation can compromise accurate compound-specific N isotope analysis of aromatic amines.
AB - Solid-phase microextraction (SPME) coupled to gas chromatography/isotope ratio mass spectrometry (GC/IRMS) was used to elucidate the effects of N-atom protonation on the analysis of N and C isotope signatures of selected aromatic amines. Precise and accurate isotope ratios were measured using polydimethylsiloxane/divinylbenzene (PDMS/DVB) as the SPME fiber material at solution pH-values that exceeded the pKa of the substituted aniline's conjugate acid by two pH-units. Deviations of d15N and d 13C-values from reference measurements by elemental analyzer IRMS were small (<0.9%0) and within the typical uncertainties of isotope ratio measurements by SPME-GC/IRMS. Under these conditions, the detection limits for accurate isotope ratio measurements were between 0.64 and 2.1 mg L-1 for d15N and between 0.13 and 0.54 mg L -1 for d13C, respectively. Substantial inverse N isotope fractionation was observed by SPME-GC/IRMS as the fraction of protonated species increased with decreasing pH leading to deviations of -20%0 while the corresponding d13C-values were largely invariant. From isotope ratio analysis at different solution pHs and theoretical calculations by density functional theory, we derived equilibrium isotope effects, EIEs, pertinent to aromatic amine protonation of 0.980 and 1.001 for N and C, respectively, which were very similar for all compounds investigated. Our work shows that N-atom protonation can compromise accurate compound-specific N isotope analysis of aromatic amines.
UR - http://www.scopus.com/inward/record.url?scp=79952176463&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=79952176463&partnerID=8YFLogxK
U2 - 10.1021/ac102667y
DO - 10.1021/ac102667y
M3 - Article
C2 - 21302936
AN - SCOPUS:79952176463
SN - 0003-2700
VL - 83
SP - 1641
EP - 1648
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 5
ER -