T1 - Performance characteristics of serologic tests for human immunodeficiency virus type 1 (HIV-1) antibody among Minnesota blood donors. Public health and clinical implications
AU - MacDonald, K. L.
AU - Jackson, J. B.
AU - Bowman, R. J.
AU - Polesky, H. F.
AU - Rhame, F. S.
AU - Balfour, Henry H
AU - Osterholm, Michael T
N1 - Copyright:
Copyright 2018 Elsevier B.V., All rights reserved.
PY - 1989
Y1 - 1989
N2 - Study Objective: To evaluate performance characteristics of sequential enzyme immunoassay (EIA) and Western blot human immunodeficiency virus type 1 (HIV-1) antibody testing in a low-risk population. Design: Three-year prospective study of a selected sample from a community-based population. Setting: Two blood collection facilities in Minnesota. Population: Minnesota blood donors. Results: During the study period, 630,190 units of blood (donations) from an estimated 290,110 Minnesota-resident donors were screened for HIV-1 antibody. Seventeen Minnesota-resident donors were identified as positive for HIV-1 antibody. Sixteen donors were available for follow-up HIV-1 culture: all were culture positive. The other donor, who was not available for follow-up culture, was likely infected with HIV-1 based on a history of high-risk behavior and positive serologic findings for hepatitis B surface antigen. Using 95% binomial confidence intervals, performance characteristics for sequential EIA and Western blot HIV-1 antibody serology were as follows: false-positive rate by number of donations, 0% to 0.0006%; specificity by number of donations, 99.9994% to 100%; predictive value of a positive test, 81% to 100%. Conclusions: In this low-risk population, the false-positive rate of serologic tests for HIV-1 antibody, using HIV-1 culture as the definitive standard for infection status, was extremely low and test specificity was extremely high.
AB - Study Objective: To evaluate performance characteristics of sequential enzyme immunoassay (EIA) and Western blot human immunodeficiency virus type 1 (HIV-1) antibody testing in a low-risk population. Design: Three-year prospective study of a selected sample from a community-based population. Setting: Two blood collection facilities in Minnesota. Population: Minnesota blood donors. Results: During the study period, 630,190 units of blood (donations) from an estimated 290,110 Minnesota-resident donors were screened for HIV-1 antibody. Seventeen Minnesota-resident donors were identified as positive for HIV-1 antibody. Sixteen donors were available for follow-up HIV-1 culture: all were culture positive. The other donor, who was not available for follow-up culture, was likely infected with HIV-1 based on a history of high-risk behavior and positive serologic findings for hepatitis B surface antigen. Using 95% binomial confidence intervals, performance characteristics for sequential EIA and Western blot HIV-1 antibody serology were as follows: false-positive rate by number of donations, 0% to 0.0006%; specificity by number of donations, 99.9994% to 100%; predictive value of a positive test, 81% to 100%. Conclusions: In this low-risk population, the false-positive rate of serologic tests for HIV-1 antibody, using HIV-1 culture as the definitive standard for infection status, was extremely low and test specificity was extremely high.
UR - http://www.scopus.com/inward/record.url?scp=0024562728&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0024562728&partnerID=8YFLogxK
U2 - 10.7326/0003-4819-110-8-617
DO - 10.7326/0003-4819-110-8-617
M3 - Article
C2 - 2648922
AN - SCOPUS:0024562728
SN - 0003-4819
VL - 110
SP - 617
EP - 621
JO - Annals of internal medicine
JF - Annals of internal medicine
IS - 8
ER -