TY - JOUR
T1 - Patterns of microparticles in blank samples
T2 - A study to inform best practices for microplastic analysis
AU - Munno, Keenan
AU - Lusher, Amy L.
AU - Minor, Elizabeth C.
AU - Gray, Andrew
AU - Ho, Kay
AU - Hankett, Jeanne
AU - T Lee, Chih Fen
AU - Primpke, Sebastian
AU - McNeish, Rachel E.
AU - Wong, Charles S.
AU - Rochman, Chelsea
N1 - Publisher Copyright:
© 2023 Elsevier Ltd
PY - 2023/8
Y1 - 2023/8
N2 - Quality assurance and quality control (QA/QC) techniques are critical to analytical chemistry, and thus the analysis of microplastics. Procedural blanks are a key component of QA/QC for quantifying and characterizing background contamination. Although procedural blanks are becoming increasingly common in microplastics research, how researchers acquire a blank and report and/or use blank contamination data varies. Here, we use the results of laboratory procedural blanks from a method evaluation study to inform QA/QC procedures for microplastics quantification and characterization. Suspected microplastic contamination in the procedural blanks, collected by 12 participating laboratories, had between 7 and 511 particles, with a mean of 80 particles per sample (±SD 134). The most common color and morphology reported were black fibers, and the most common size fraction reported was 20–212 μm. The lack of even smaller particles is likely due to limits of detection versus lack of contamination, as very few labs reported particles <20 μm. Participating labs used a range of QA/QC techniques, including air filtration, filtered water, and working in contained/‘enclosed’ environments. Our analyses showed that these procedures did not significantly affect blank contamination. To inform blank subtraction, several subtraction methods were tested. No clear pattern based on total recovery was observed. Despite our results, we recommend commonly accepted procedures such as thorough training and cleaning procedures, air filtration, filtered water (e.g., MilliQ, deionized or reverse osmosis), non-synthetic clothing policies and ‘enclosed’ air flow systems (e.g., clean cabinet). We also recommend blank subtracting by a combination of particle characteristics (color, morphology and size fraction), as it likely provides final microplastic particle characteristics that are most representative of the sample. Further work should be done to assess other QA/QC parameters, such as the use of other types of blanks (e.g., field blanks, matrix blanks) and limits of detection and quantification.
AB - Quality assurance and quality control (QA/QC) techniques are critical to analytical chemistry, and thus the analysis of microplastics. Procedural blanks are a key component of QA/QC for quantifying and characterizing background contamination. Although procedural blanks are becoming increasingly common in microplastics research, how researchers acquire a blank and report and/or use blank contamination data varies. Here, we use the results of laboratory procedural blanks from a method evaluation study to inform QA/QC procedures for microplastics quantification and characterization. Suspected microplastic contamination in the procedural blanks, collected by 12 participating laboratories, had between 7 and 511 particles, with a mean of 80 particles per sample (±SD 134). The most common color and morphology reported were black fibers, and the most common size fraction reported was 20–212 μm. The lack of even smaller particles is likely due to limits of detection versus lack of contamination, as very few labs reported particles <20 μm. Participating labs used a range of QA/QC techniques, including air filtration, filtered water, and working in contained/‘enclosed’ environments. Our analyses showed that these procedures did not significantly affect blank contamination. To inform blank subtraction, several subtraction methods were tested. No clear pattern based on total recovery was observed. Despite our results, we recommend commonly accepted procedures such as thorough training and cleaning procedures, air filtration, filtered water (e.g., MilliQ, deionized or reverse osmosis), non-synthetic clothing policies and ‘enclosed’ air flow systems (e.g., clean cabinet). We also recommend blank subtracting by a combination of particle characteristics (color, morphology and size fraction), as it likely provides final microplastic particle characteristics that are most representative of the sample. Further work should be done to assess other QA/QC parameters, such as the use of other types of blanks (e.g., field blanks, matrix blanks) and limits of detection and quantification.
KW - Controls
KW - Cross contamination
KW - Methods
KW - Plastic
KW - Procedural contamination
KW - QA/QC
UR - http://www.scopus.com/inward/record.url?scp=85159187529&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85159187529&partnerID=8YFLogxK
U2 - 10.1016/j.chemosphere.2023.138883
DO - 10.1016/j.chemosphere.2023.138883
M3 - Article
C2 - 37169088
AN - SCOPUS:85159187529
SN - 0045-6535
VL - 333
JO - Chemosphere
JF - Chemosphere
M1 - 138883
ER -