TY - JOUR
T1 - Paper-based potentiometric ion sensing
AU - Lan, Wen Jie
AU - Zou, Xu U.
AU - Hamedi, Mahiar M.
AU - Hu, Jinbo
AU - Parolo, Claudio
AU - Maxwell, E. Jane
AU - Bühlmann, Philippe
AU - Whitesides, George M.
N1 - Publisher Copyright:
© 2014 American Chemical Society.
PY - 2014/10/7
Y1 - 2014/10/7
N2 - This paper describes the design and fabrication of ion-sensing electrochemical paper-based analytical devices (EPADs) in which a miniaturized paper reference electrode is integrated with a small ion-selective paper electrode (ISPE) for potentiometric measurements. Ion-sensing EPADs use printed wax barriers to define electrochemical sample and reference zones. Single-layer EPADs for sensing of chloride ions include wax-defined sample and reference zones that each incorporate a Ag/AgCl electrode. In EPADs developed for other electrolytes (potassium, sodium, and calcium ions), a PVC-based ion-selective membrane is added to separate the sample zone from a paper indicator electrode. After the addition of a small volume (less than 10 μL) of sample and reference solutions to different zones, ion-sensing EPADs exhibit a linear response, over 3 orders of magnitude, in ranges of electrolyte concentrations that are relevant to a variety of applications, with a slope close to the theoretical value (59.2/z mV). Ion-selective EPADs provide a portable, inexpensive, and disposable way of measuring concentrations of electrolyte ions in aqueous solutions.
AB - This paper describes the design and fabrication of ion-sensing electrochemical paper-based analytical devices (EPADs) in which a miniaturized paper reference electrode is integrated with a small ion-selective paper electrode (ISPE) for potentiometric measurements. Ion-sensing EPADs use printed wax barriers to define electrochemical sample and reference zones. Single-layer EPADs for sensing of chloride ions include wax-defined sample and reference zones that each incorporate a Ag/AgCl electrode. In EPADs developed for other electrolytes (potassium, sodium, and calcium ions), a PVC-based ion-selective membrane is added to separate the sample zone from a paper indicator electrode. After the addition of a small volume (less than 10 μL) of sample and reference solutions to different zones, ion-sensing EPADs exhibit a linear response, over 3 orders of magnitude, in ranges of electrolyte concentrations that are relevant to a variety of applications, with a slope close to the theoretical value (59.2/z mV). Ion-selective EPADs provide a portable, inexpensive, and disposable way of measuring concentrations of electrolyte ions in aqueous solutions.
UR - http://www.scopus.com/inward/record.url?scp=84907898130&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84907898130&partnerID=8YFLogxK
U2 - 10.1021/ac5018088
DO - 10.1021/ac5018088
M3 - Article
C2 - 25197763
AN - SCOPUS:84907898130
SN - 0003-2700
VL - 86
SP - 9548
EP - 9553
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 19
ER -