TY - JOUR
T1 - Osmotic water permeability of the human red cell
T2 - Dependence on direction of water flow and cell volume
AU - Mlekoday, Henry J.
AU - Moore, Richard
AU - Levitt, David G.
PY - 1983/2/1
Y1 - 1983/2/1
N2 - The osmotic permeability coefficient (Pf) was measured with a stopped-flow light-scattering technique. There is an artifactual light-scattering signal produced by the initial mixing that decays with a half-time of ~0.2 s. This seriously interferes with the measurement of the osmotically induced change in cell volume, which has a similar half-time. This "injection artifact" is associated with the biconcave shape of the cells. It is negligible for cells that have been made nearly spherical by swelling them in 160 mosmol. The dependence of this artifact on the cell volume may explain the previously observed dependence of Pf on the cell volume. When cells are made echinocytic (and therefore spherically symmetric), this injection artifact becomes negligible at all cell volumes and Pf can be accurately measured. The Pf of echinocytic cells was nearly constant, varying by <10% with the direction of flow and the medium osmolarity (160-360 mosmol). The average value of Pf was 2.0 × 10-2 cm/s (T = 23°C).
AB - The osmotic permeability coefficient (Pf) was measured with a stopped-flow light-scattering technique. There is an artifactual light-scattering signal produced by the initial mixing that decays with a half-time of ~0.2 s. This seriously interferes with the measurement of the osmotically induced change in cell volume, which has a similar half-time. This "injection artifact" is associated with the biconcave shape of the cells. It is negligible for cells that have been made nearly spherical by swelling them in 160 mosmol. The dependence of this artifact on the cell volume may explain the previously observed dependence of Pf on the cell volume. When cells are made echinocytic (and therefore spherically symmetric), this injection artifact becomes negligible at all cell volumes and Pf can be accurately measured. The Pf of echinocytic cells was nearly constant, varying by <10% with the direction of flow and the medium osmolarity (160-360 mosmol). The average value of Pf was 2.0 × 10-2 cm/s (T = 23°C).
UR - http://www.scopus.com/inward/record.url?scp=0020655913&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0020655913&partnerID=8YFLogxK
U2 - 10.1085/jgp.81.2.213
DO - 10.1085/jgp.81.2.213
M3 - Article
C2 - 6842172
AN - SCOPUS:0020655913
SN - 0022-1295
VL - 81
SP - 213
EP - 220
JO - Journal of General Physiology
JF - Journal of General Physiology
IS - 2
ER -