Abstract
Heat transfer rates from a surface can be determined from the slope of the temperature profile measured with a thermocouple wire traversing within a boundary layer. However, accuracy of such measurement can suffer due to flow distortion and conduction through the thermocouple wire. The present numerical study consists of two parts-a 2D simulation of flow distortion due to a cylinder in cross flow near a solid wall and a 3D simulation defined as a fin problem to calculate the thermal profile measurement error due to conduction through the thermocouple wires. Results show that the measured temperature is lower than the true temperature resulting in a 5% under-prediction of local heat transfer coefficient. A parametric study shows that low thermal conductivity thermocouple (E type) with a small wire diameter (76 micron) is desirable to reduce the measurement error in local Nusselt number.
Original language | English (US) |
---|---|
Pages (from-to) | 869-877 |
Number of pages | 9 |
Journal | Heat and Mass Transfer/Waerme- und Stoffuebertragung |
Volume | 47 |
Issue number | 8 |
DOIs | |
State | Published - Aug 2011 |