Numerical and experimental investigation of heat transfer in a solar receiver with a variable aperture

Mostafa Abuseada, Nesrin Ozalp, Cédric Ophoff

Research output: Contribution to journalArticle

Abstract

Variable aperture can assist in maintaining semi-constant temperatures within a receiver's cavity under transient solar loading. An in-house code has been developed to model a receiver and effectively control its components to achieve semi-constant temperatures under transients. The code consists of a full optical analysis performed via the Monte Carlo ray tracing method in addition to a transient two-dimensional heat transfer analysis. The system studied consists of a cavity type solar receiver with 60 mm radius fixed aperture on the cavity body, a variable aperture mechanism mounted on the receiver's flange, and a 7 kW Xenon arc solar simulator. A composite shape consisting of a hemisphere attached to a cylinder is proposed to model the Xenon arc. The in-house code has been experimentally validated through experimental tests for different input currents to the solar simulator, volumetric flow rates, and aperture's radii. The optical analysis was validated based on heat flux measurements, where it had percentage errors of 0.8, 0.5, 1.1, and 3.2% for the peak power, total power, half width, and half power. For the heat transfer model, percentage errors of 3.2, 2.9, and 5.3% at the inlet, center, and outlet sections of the receiver were determined for different flow rates using maximum input current and opening radius. The aperture mechanism was capable of maintaining an exhaust temperature of 250 °C based on actual Direct Normal Irradiance data. Results showed that the variable aperture is a promising apparatus even in applications where the maximum temperatures are desired based on an observed optimum radius of 57.5 mm.

LanguageEnglish (US)
Pages125-135
Number of pages11
JournalInternational Journal of Heat and Mass Transfer
Volume128
DOIs
StatePublished - Jan 1 2019

Fingerprint

solar collectors
apertures
heat transfer
Heat transfer
Xenon
receivers
solar simulators
radii
Receivers (containers)
Simulators
Flow rate
Temperature
xenon
cavities
Ray tracing
flow velocity
arcs
Flanges
Heat flux
flanges

Keywords

  • Monte Carlo ray tracing
  • Optical analysis
  • Radiation heat transfer
  • Solar receiver
  • Variable aperture

Cite this

Numerical and experimental investigation of heat transfer in a solar receiver with a variable aperture. / Abuseada, Mostafa; Ozalp, Nesrin; Ophoff, Cédric.

In: International Journal of Heat and Mass Transfer, Vol. 128, 01.01.2019, p. 125-135.

Research output: Contribution to journalArticle

@article{ca0d8aa358d54e7ea53e3ac64fd2539a,
title = "Numerical and experimental investigation of heat transfer in a solar receiver with a variable aperture",
abstract = "Variable aperture can assist in maintaining semi-constant temperatures within a receiver's cavity under transient solar loading. An in-house code has been developed to model a receiver and effectively control its components to achieve semi-constant temperatures under transients. The code consists of a full optical analysis performed via the Monte Carlo ray tracing method in addition to a transient two-dimensional heat transfer analysis. The system studied consists of a cavity type solar receiver with 60 mm radius fixed aperture on the cavity body, a variable aperture mechanism mounted on the receiver's flange, and a 7 kW Xenon arc solar simulator. A composite shape consisting of a hemisphere attached to a cylinder is proposed to model the Xenon arc. The in-house code has been experimentally validated through experimental tests for different input currents to the solar simulator, volumetric flow rates, and aperture's radii. The optical analysis was validated based on heat flux measurements, where it had percentage errors of 0.8, 0.5, 1.1, and 3.2{\%} for the peak power, total power, half width, and half power. For the heat transfer model, percentage errors of 3.2, 2.9, and 5.3{\%} at the inlet, center, and outlet sections of the receiver were determined for different flow rates using maximum input current and opening radius. The aperture mechanism was capable of maintaining an exhaust temperature of 250 °C based on actual Direct Normal Irradiance data. Results showed that the variable aperture is a promising apparatus even in applications where the maximum temperatures are desired based on an observed optimum radius of 57.5 mm.",
keywords = "Monte Carlo ray tracing, Optical analysis, Radiation heat transfer, Solar receiver, Variable aperture",
author = "Mostafa Abuseada and Nesrin Ozalp and C{\'e}dric Ophoff",
year = "2019",
month = "1",
day = "1",
doi = "10.1016/j.ijheatmasstransfer.2018.08.121",
language = "English (US)",
volume = "128",
pages = "125--135",
journal = "International Journal of Heat and Mass Transfer",
issn = "0017-9310",
publisher = "Elsevier Limited",

}

TY - JOUR

T1 - Numerical and experimental investigation of heat transfer in a solar receiver with a variable aperture

AU - Abuseada, Mostafa

AU - Ozalp, Nesrin

AU - Ophoff, Cédric

PY - 2019/1/1

Y1 - 2019/1/1

N2 - Variable aperture can assist in maintaining semi-constant temperatures within a receiver's cavity under transient solar loading. An in-house code has been developed to model a receiver and effectively control its components to achieve semi-constant temperatures under transients. The code consists of a full optical analysis performed via the Monte Carlo ray tracing method in addition to a transient two-dimensional heat transfer analysis. The system studied consists of a cavity type solar receiver with 60 mm radius fixed aperture on the cavity body, a variable aperture mechanism mounted on the receiver's flange, and a 7 kW Xenon arc solar simulator. A composite shape consisting of a hemisphere attached to a cylinder is proposed to model the Xenon arc. The in-house code has been experimentally validated through experimental tests for different input currents to the solar simulator, volumetric flow rates, and aperture's radii. The optical analysis was validated based on heat flux measurements, where it had percentage errors of 0.8, 0.5, 1.1, and 3.2% for the peak power, total power, half width, and half power. For the heat transfer model, percentage errors of 3.2, 2.9, and 5.3% at the inlet, center, and outlet sections of the receiver were determined for different flow rates using maximum input current and opening radius. The aperture mechanism was capable of maintaining an exhaust temperature of 250 °C based on actual Direct Normal Irradiance data. Results showed that the variable aperture is a promising apparatus even in applications where the maximum temperatures are desired based on an observed optimum radius of 57.5 mm.

AB - Variable aperture can assist in maintaining semi-constant temperatures within a receiver's cavity under transient solar loading. An in-house code has been developed to model a receiver and effectively control its components to achieve semi-constant temperatures under transients. The code consists of a full optical analysis performed via the Monte Carlo ray tracing method in addition to a transient two-dimensional heat transfer analysis. The system studied consists of a cavity type solar receiver with 60 mm radius fixed aperture on the cavity body, a variable aperture mechanism mounted on the receiver's flange, and a 7 kW Xenon arc solar simulator. A composite shape consisting of a hemisphere attached to a cylinder is proposed to model the Xenon arc. The in-house code has been experimentally validated through experimental tests for different input currents to the solar simulator, volumetric flow rates, and aperture's radii. The optical analysis was validated based on heat flux measurements, where it had percentage errors of 0.8, 0.5, 1.1, and 3.2% for the peak power, total power, half width, and half power. For the heat transfer model, percentage errors of 3.2, 2.9, and 5.3% at the inlet, center, and outlet sections of the receiver were determined for different flow rates using maximum input current and opening radius. The aperture mechanism was capable of maintaining an exhaust temperature of 250 °C based on actual Direct Normal Irradiance data. Results showed that the variable aperture is a promising apparatus even in applications where the maximum temperatures are desired based on an observed optimum radius of 57.5 mm.

KW - Monte Carlo ray tracing

KW - Optical analysis

KW - Radiation heat transfer

KW - Solar receiver

KW - Variable aperture

UR - http://www.scopus.com/inward/record.url?scp=85052739528&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85052739528&partnerID=8YFLogxK

U2 - 10.1016/j.ijheatmasstransfer.2018.08.121

DO - 10.1016/j.ijheatmasstransfer.2018.08.121

M3 - Article

VL - 128

SP - 125

EP - 135

JO - International Journal of Heat and Mass Transfer

T2 - International Journal of Heat and Mass Transfer

JF - International Journal of Heat and Mass Transfer

SN - 0017-9310

ER -