TY - GEN
T1 - Nonlinear post-beamforming filtering of pulse-echo ultrasound for contrast enhancement
AU - Ebbini, Emad S.
PY - 2009
Y1 - 2009
N2 - We have recently validated the use of a second-order Volterra (SoVF) model for separating the linear and quadratic components of the beamformed radio frequency (RF) data in pulseecho ultrasonic imaging. The quadratic component captures the second order nonlinearities in the echo data. Grayscale images from the quadratic component, referred to as quadratic B-mode (QB-mode) images, typically have higher contrast and increased dynamic range than the standard B-mode images (without loss in spatial resolution). An SVD-based algorithm for finding the coefficients of the SoVF based on a linear plus quadratic prediction model of the RF data was developed and validated in a variety of imaging situations, including in vivo. This approach, while successful, may produce images with ripple artifacts due to the truncation of the kernel. Adaptive SoVF implementations based on both LMS and RLS methods have been developed and are shown to produce artifact-free QB-mode images using relatively small kernels, i.e. well suited for real-time implementation. In this paper, we show results of imaging microbubble ultrasound contrast agents (UCAs) to demonstrate the increased sensitivity and specificity of QB-mode imaging compared to conventional methods.
AB - We have recently validated the use of a second-order Volterra (SoVF) model for separating the linear and quadratic components of the beamformed radio frequency (RF) data in pulseecho ultrasonic imaging. The quadratic component captures the second order nonlinearities in the echo data. Grayscale images from the quadratic component, referred to as quadratic B-mode (QB-mode) images, typically have higher contrast and increased dynamic range than the standard B-mode images (without loss in spatial resolution). An SVD-based algorithm for finding the coefficients of the SoVF based on a linear plus quadratic prediction model of the RF data was developed and validated in a variety of imaging situations, including in vivo. This approach, while successful, may produce images with ripple artifacts due to the truncation of the kernel. Adaptive SoVF implementations based on both LMS and RLS methods have been developed and are shown to produce artifact-free QB-mode images using relatively small kernels, i.e. well suited for real-time implementation. In this paper, we show results of imaging microbubble ultrasound contrast agents (UCAs) to demonstrate the increased sensitivity and specificity of QB-mode imaging compared to conventional methods.
KW - Beamforming
KW - Contrast enhancement
KW - Inverse filtering
KW - Pulse-echo ultrasound
KW - Volterra filters
UR - http://www.scopus.com/inward/record.url?scp=77951961894&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77951961894&partnerID=8YFLogxK
U2 - 10.1109/ICIP.2009.5414098
DO - 10.1109/ICIP.2009.5414098
M3 - Conference contribution
AN - SCOPUS:77951961894
SN - 9781424456543
T3 - Proceedings - International Conference on Image Processing, ICIP
SP - 2641
EP - 2644
BT - 2009 IEEE International Conference on Image Processing, ICIP 2009 - Proceedings
PB - IEEE Computer Society
T2 - 2009 IEEE International Conference on Image Processing, ICIP 2009
Y2 - 7 November 2009 through 10 November 2009
ER -