Abstract

Microelectrodes have been used for the measurement of oxygen tension in various biological systems.(Silver, 1987) Although not previously reported, microelectrodes allow the direct measurement of oxygen tension profiles within collagen gels containing entrapped hepatocytes (collagcn-hepatocyte gels). These oxygen tension profiles, along with hepatocyte oxygen consumption data, allowed the estimation of a diffusion coefficient for oxygen in collagen-hepatocyte gels, Dg = 2.99 × 10-5 cm2/s.

Original languageEnglish (US)
Pages (from-to)449-452
Number of pages4
JournalBiotechnology Techniques
Volume5
Issue number6
DOIs
StatePublished - Nov 1 1991

Fingerprint

Microelectrodes
Collagen
Hepatocytes
Gels
Oxygen
Silver
Oxygen Consumption
Biological systems

Cite this

Nyberg, S. L., Santilli, S. M., Shatford, R. A., Cerra, F. B., Knighton, D. R., & Hu, W. S. (1991). Microelectrode measurement of oxygen tensions in collagen-hepatocyte gels. Biotechnology Techniques, 5(6), 449-452. https://doi.org/10.1007/BF00155491

Microelectrode measurement of oxygen tensions in collagen-hepatocyte gels. / Nyberg, Scott L.; Santilli, Steven M.; Shatford, Russell A.; Cerra, Frank B.; Knighton, David R.; Hu, Wei Shou.

In: Biotechnology Techniques, Vol. 5, No. 6, 01.11.1991, p. 449-452.

Research output: Contribution to journalArticle

Nyberg, SL, Santilli, SM, Shatford, RA, Cerra, FB, Knighton, DR & Hu, WS 1991, 'Microelectrode measurement of oxygen tensions in collagen-hepatocyte gels', Biotechnology Techniques, vol. 5, no. 6, pp. 449-452. https://doi.org/10.1007/BF00155491
Nyberg, Scott L. ; Santilli, Steven M. ; Shatford, Russell A. ; Cerra, Frank B. ; Knighton, David R. ; Hu, Wei Shou. / Microelectrode measurement of oxygen tensions in collagen-hepatocyte gels. In: Biotechnology Techniques. 1991 ; Vol. 5, No. 6. pp. 449-452.
@article{aca93ddeedf4488db825bb4a34093921,
title = "Microelectrode measurement of oxygen tensions in collagen-hepatocyte gels",
abstract = "Microelectrodes have been used for the measurement of oxygen tension in various biological systems.(Silver, 1987) Although not previously reported, microelectrodes allow the direct measurement of oxygen tension profiles within collagen gels containing entrapped hepatocytes (collagcn-hepatocyte gels). These oxygen tension profiles, along with hepatocyte oxygen consumption data, allowed the estimation of a diffusion coefficient for oxygen in collagen-hepatocyte gels, Dg = 2.99 × 10-5 cm2/s.",
author = "Nyberg, {Scott L.} and Santilli, {Steven M.} and Shatford, {Russell A.} and Cerra, {Frank B.} and Knighton, {David R.} and Hu, {Wei Shou}",
year = "1991",
month = "11",
day = "1",
doi = "10.1007/BF00155491",
language = "English (US)",
volume = "5",
pages = "449--452",
journal = "Biotechnology Letters",
issn = "0141-5492",
publisher = "Springer Netherlands",
number = "6",

}

TY - JOUR

T1 - Microelectrode measurement of oxygen tensions in collagen-hepatocyte gels

AU - Nyberg, Scott L.

AU - Santilli, Steven M.

AU - Shatford, Russell A.

AU - Cerra, Frank B.

AU - Knighton, David R.

AU - Hu, Wei Shou

PY - 1991/11/1

Y1 - 1991/11/1

N2 - Microelectrodes have been used for the measurement of oxygen tension in various biological systems.(Silver, 1987) Although not previously reported, microelectrodes allow the direct measurement of oxygen tension profiles within collagen gels containing entrapped hepatocytes (collagcn-hepatocyte gels). These oxygen tension profiles, along with hepatocyte oxygen consumption data, allowed the estimation of a diffusion coefficient for oxygen in collagen-hepatocyte gels, Dg = 2.99 × 10-5 cm2/s.

AB - Microelectrodes have been used for the measurement of oxygen tension in various biological systems.(Silver, 1987) Although not previously reported, microelectrodes allow the direct measurement of oxygen tension profiles within collagen gels containing entrapped hepatocytes (collagcn-hepatocyte gels). These oxygen tension profiles, along with hepatocyte oxygen consumption data, allowed the estimation of a diffusion coefficient for oxygen in collagen-hepatocyte gels, Dg = 2.99 × 10-5 cm2/s.

UR - http://www.scopus.com/inward/record.url?scp=0141571744&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0141571744&partnerID=8YFLogxK

U2 - 10.1007/BF00155491

DO - 10.1007/BF00155491

M3 - Article

AN - SCOPUS:0141571744

VL - 5

SP - 449

EP - 452

JO - Biotechnology Letters

JF - Biotechnology Letters

SN - 0141-5492

IS - 6

ER -