Skip to main navigation Skip to search Skip to main content

Measurement of Underivatized Propranolol Enantiomers in Serum Using a Cellulose –Tris(3,5 -Dimethylphenylcarbamate) High-Performance Liquid Chromatographic (HPLC) Chiral Stationary Phase

Research output: Contribution to journal › Article › peer-review

Abstract

A commercially available high-performance liquid chromatographic (HPLC) chiral stationary phase (HPLC-CSP) has been used to measure serum levels of d- and l-propranolol. The HPLC-CSP is based upon cellulose–tris(3,5-dimethylcarbamate) and is able to stereochemically resolve d- and l-propranolol without precolumn derivatization using a mobile phase composed of hexane:2-propranol: N,N-dimethyloctylamine (92:8:0.01, v/v/v). Under these conditions the observed stereochemical resolution (α) of the two enantiomers was α = 2.2. A subject's concentration–time curve of the two isomers was determined following the ingestion of 160 mg racemic propranolol.

Original languageEnglish (US)
Pages (from-to)187-189
Number of pages3
JournalPharmaceutical Research: An Official Journal of the American Association of Pharmaceutical Scientists
Volume5
Issue number3
DOIs
StatePublished - Mar 1988

Keywords

  • HPLC chiral stationary phase
  • enantioselective high-performance liquid chromatography (HPLC)
  • propanolol enantiomers
  • serum levels

Fingerprint

Dive into the research topics of 'Measurement of Underivatized Propranolol Enantiomers in Serum Using a Cellulose –Tris(3,5 -Dimethylphenylcarbamate) High-Performance Liquid Chromatographic (HPLC) Chiral Stationary Phase'. Together they form a unique fingerprint.

Cite this