T1 - Marginal discrepancy dimensions of single unit metal crowns fabricated by using CAD-CAM–milled acrylate resin polymer blocks or a conventional waxing technique
AU - Lalande, David
AU - Hodd, Jeffrey A.
AU - Brousseau, John S.
AU - Ramos, Van
AU - Dunham, Daniel
AU - Rueggeberg, Frederick
N1 - Publisher Copyright:
© 2018 Editorial Council for the Journal of Prosthetic Dentistry
PY - 2018/6
Y1 - 2018/6
N2 - Statement of problem: Because crowns with open margins are a well-known problem and can lead to complications, it is important to assess the accuracy of margins resulting from the use of a new technique. Currently, data regarding the marginal fit of computer-aided design and computer-aided manufacturing (CAD-CAM) technology to fabricate a complete gold crown (CGC) from a castable acrylate resin polymer block are lacking. Purpose: The purpose of this in vitro study was to compare marginal discrepancy widths of CGCs fabricated by using either conventional hand waxing or acrylate resin polymer blocks generated by using CAD-CAM technology. Material and methods: A plastic model of a first mandibular molar was prepared by using a 1-mm, rounded chamfer margin on the entire circumference of the tooth. The master die was duplicated 30 times, and 15 wax patterns were fabricated by using a manual waxing technique, and 15 were fabricated by using CAD-CAM technology. All patterns were invested and cast, and resulting CGCs were cemented on their respective die by using resin-modified glass ionomer cement. The specimens were then embedded in acrylic resin and sectioned buccolingually. The buccal and lingual marginal discrepancies of each sectioned portion were measured by using microscopy at ×50 magnification. Data were subjected to repeated measures 2-way ANOVA, by using the Tukey post hoc pairwise comparison test (α=.05). Results: The factor of “technique” had no significant influence on marginal discrepancy measurement (P=.431), but a significant effect of “margin location” (P=.019) was noted. The confounding combination of factors was found to be significantly lower marginal discrepancy dimensions of the lingual margin discrepancy than on the buccal side by using CAD-CAM technology. Conclusions: The marginal discrepancy of CAD-CAM acrylate resin crowns was not significantly different from those made with a conventional manual method; however, lingual margin discrepancies present from CAD-CAM–prepared crowns were significantly less than those measured on the respective buccal surface.
AB - Statement of problem: Because crowns with open margins are a well-known problem and can lead to complications, it is important to assess the accuracy of margins resulting from the use of a new technique. Currently, data regarding the marginal fit of computer-aided design and computer-aided manufacturing (CAD-CAM) technology to fabricate a complete gold crown (CGC) from a castable acrylate resin polymer block are lacking. Purpose: The purpose of this in vitro study was to compare marginal discrepancy widths of CGCs fabricated by using either conventional hand waxing or acrylate resin polymer blocks generated by using CAD-CAM technology. Material and methods: A plastic model of a first mandibular molar was prepared by using a 1-mm, rounded chamfer margin on the entire circumference of the tooth. The master die was duplicated 30 times, and 15 wax patterns were fabricated by using a manual waxing technique, and 15 were fabricated by using CAD-CAM technology. All patterns were invested and cast, and resulting CGCs were cemented on their respective die by using resin-modified glass ionomer cement. The specimens were then embedded in acrylic resin and sectioned buccolingually. The buccal and lingual marginal discrepancies of each sectioned portion were measured by using microscopy at ×50 magnification. Data were subjected to repeated measures 2-way ANOVA, by using the Tukey post hoc pairwise comparison test (α=.05). Results: The factor of “technique” had no significant influence on marginal discrepancy measurement (P=.431), but a significant effect of “margin location” (P=.019) was noted. The confounding combination of factors was found to be significantly lower marginal discrepancy dimensions of the lingual margin discrepancy than on the buccal side by using CAD-CAM technology. Conclusions: The marginal discrepancy of CAD-CAM acrylate resin crowns was not significantly different from those made with a conventional manual method; however, lingual margin discrepancies present from CAD-CAM–prepared crowns were significantly less than those measured on the respective buccal surface.
UR - http://www.scopus.com/inward/record.url?scp=85031326328&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85031326328&partnerID=8YFLogxK
U2 - 10.1016/j.prosdent.2017.07.019
DO - 10.1016/j.prosdent.2017.07.019
M3 - Article
C2 - 29042116
AN - SCOPUS:85031326328
SN - 0022-3913
VL - 119
SP - 948
EP - 953
JO - Journal of Prosthetic Dentistry
JF - Journal of Prosthetic Dentistry
IS - 6
ER -