Abstract
Multi-energy CT can be used to decompose CT images into different material bases to allow for the quantification of materials. Three-material decomposition is desirable for clinical applications such as K-edge imaging. However, three-material decomposition requires measurements at 3 or more energies or additional assumptions such as volume conservation. This work concerns the following questions: 1) For photon counting detector (PCD) CT with only two energy bins, can the joint use of the PCD and kV-switching improve the performance of three-material decomposition for K-edge imaging? 2) If the PCD energy threshold must be fixed for both kV levels, how can its optimal value be pre-determined for a given K-edge imaging task? 3) While in conventional kV-switching multi-energy CT the separation of the two kV levels needs to be as wide as achievable, is this still the case when kV-switching is jointly used with a dual-bin PCD? These questions were answered by performing Craḿer-Rao lower bound (CRLB) analysis for dual-bin PCD-CT with kV-switching to optimize the PCD threshold and kV levels for the decomposition of water, iodine, and gadolinium bases using a previously modeled CdTe PCD energy response function. Experimental dual-bin PCD-CT images were acquired with kV-switching, and without kV-switching but with the volume conservation constraint, using the optimal acquisition parameters obtained from the CRLB analysis. Dual-bin PCD-CT with kV-switching allowed separation of all three basis materials with improved quantitative accuracy over dual-bin PCD-CT without kV-switching, which also suffered from poorer material separation and residual or missing signals from other materials.
| Original language | English (US) |
|---|---|
| Title of host publication | Medical Imaging 2023 |
| Subtitle of host publication | Physics of Medical Imaging |
| Editors | Lifeng Yu, Rebecca Fahrig, John M. Sabol |
| Publisher | SPIE |
| ISBN (Electronic) | 9781510660311 |
| DOIs | |
| State | Published - 2023 |
| Externally published | Yes |
| Event | Medical Imaging 2023: Physics of Medical Imaging - San Diego, United States Duration: Feb 19 2023 → Feb 23 2023 |
Publication series
| Name | Progress in Biomedical Optics and Imaging - Proceedings of SPIE |
|---|---|
| Volume | 12463 |
| ISSN (Print) | 1605-7422 |
Conference
| Conference | Medical Imaging 2023: Physics of Medical Imaging |
|---|---|
| Country/Territory | United States |
| City | San Diego |
| Period | 2/19/23 → 2/23/23 |
Bibliographical note
Publisher Copyright:© COPYRIGHT SPIE. Downloading of the abstract is permitted for personal use only.
Fingerprint
Dive into the research topics of 'K-edge photon counting CT imaging using a dual-bin photon counting detector and kV switching'. Together they form a unique fingerprint.Cite this
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS