TY - JOUR
T1 - Intersession repeatability of macular thickness measurements with the Humphrey 2000 OCT
AU - Koozekanani, Dara
AU - Roberts, Cynthia
AU - Katz, Steven E.
AU - Herderick, Ed E.
PY - 2000
Y1 - 2000
N2 - PURPOSE. This study was designed to determine intersession repeatability of measurements of macular thickness made with a commercially available optical coherence tomography (OCT) system. The images that can be routinely acquired with the commercial instrument differ significantly in quality from the images in the literature, which have mostly been acquired on prototype systems. METHODS. Multiple OCT images of the nasal macula were obtained from the right eye during three independent measuring sessions, using the Humphrey 2000 OCT system (Humphrey, San Leandro, CA). Twenty-six volunteers with no history of ocular disease participated in this investigation. Eyes in all subjects were undilated during scan acquisition. Scans were horizontal, 3 mm long, and through the fovea. Five scans were used from each session, for a total of 15 scans per subject. Retinal boundaries were automatically detected using custom software. Statistical software was used to calculate intersession and intrasession repeatability. Manual correction was performed on the automatically detected boundaries, and a second analysis was performed using these boundaries. RESULTS. When no manual correction of boundaries was performed, there were no significant effects between different sessions (P = 0.529) or between different scans within the same session (P = 0.509). Average retinal thickness was found to be 274 ± 17 μm for a 1-mm long region 0.75 mm from the fovea. Individual scan averages differed from overall patient averages by 0 ± 4.3 μm (99% confidence interval, 11.2 μm). CONCLUSIONS. OCT measurements of macular thickness made with the Humphrey 2000 OCT system are repeatable over different sessions with an expected variation of less than 11 μm (99% confidence interval).
AB - PURPOSE. This study was designed to determine intersession repeatability of measurements of macular thickness made with a commercially available optical coherence tomography (OCT) system. The images that can be routinely acquired with the commercial instrument differ significantly in quality from the images in the literature, which have mostly been acquired on prototype systems. METHODS. Multiple OCT images of the nasal macula were obtained from the right eye during three independent measuring sessions, using the Humphrey 2000 OCT system (Humphrey, San Leandro, CA). Twenty-six volunteers with no history of ocular disease participated in this investigation. Eyes in all subjects were undilated during scan acquisition. Scans were horizontal, 3 mm long, and through the fovea. Five scans were used from each session, for a total of 15 scans per subject. Retinal boundaries were automatically detected using custom software. Statistical software was used to calculate intersession and intrasession repeatability. Manual correction was performed on the automatically detected boundaries, and a second analysis was performed using these boundaries. RESULTS. When no manual correction of boundaries was performed, there were no significant effects between different sessions (P = 0.529) or between different scans within the same session (P = 0.509). Average retinal thickness was found to be 274 ± 17 μm for a 1-mm long region 0.75 mm from the fovea. Individual scan averages differed from overall patient averages by 0 ± 4.3 μm (99% confidence interval, 11.2 μm). CONCLUSIONS. OCT measurements of macular thickness made with the Humphrey 2000 OCT system are repeatable over different sessions with an expected variation of less than 11 μm (99% confidence interval).
UR - http://www.scopus.com/inward/record.url?scp=0034058189&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0034058189&partnerID=8YFLogxK
M3 - Article
C2 - 10798667
AN - SCOPUS:0034058189
SN - 0146-0404
VL - 41
SP - 1486
EP - 1491
JO - Investigative Ophthalmology and Visual Science
JF - Investigative Ophthalmology and Visual Science
IS - 6
ER -