Skip to main navigation Skip to search Skip to main content

Influence of graphene oxide filler content on the dentin bond integrity, degree of conversion and bond strength of experimental adhesive. A SEM, micro-Raman, FTIR and microtensile study

  • Mohammed S. Bin-Shuwaish
  • , Ahmed M. Maawadh
  • , Rana S. Al-Hamdan
  • , Saad Alresayes
  • , Thamer Ali
  • , Basil Almutairi
  • , Fahim Vohra
  • , Tariq Abduljabbar

Research output: Contribution to journal › Article › peer-review

Abstract

The study aimed to evaluate the effect of graphene oxide (GO) nano-filler content in experimental dental adhesive on its degree of conversion (DC), microtensile bond strength (μTBS) and structural reliability, using Fourier transform infrared spectroscopy (FTIR), Micro-Raman spectroscopy and Scanning electron microscopy (SEM). A resin adhesive was fabricated (control adhesive - CA) and fabricated GO nano-particles were added at 0.5% and 2.0% (m/m) to produce adhesives GOA1 and GOA2 respectively. One hundred and two teeth (specimens) were prepared for dentin exposure and conditioned with 36% phosphoric acid. Specimens in each group (n = 34) were treated with formulated adhesives (CA, GOA1 GOA2) and photo-polymerized for 20 s followed by composite build up. Sixty specimens were used for μTBS testing in the adhesive groups (CA, GOA1 GOA2), with half exposed to thermocycling (TC) whereas the remaining half (n = 10) stored in distilled water. Seven specimens each were assessed using SEM and Micro-Raman spectroscopy, in each adhesive group (n = 7). DC for the adhesives was assessed using FTIR. The means of μTBS and DC were analyzed using ANOVA and post hoc Tukey multiple comparisons test. GO nano-filler content showed significant influence on the adhesive μTBS in comparison to controls (p < 0.01). Ageing (TC) revealed significant reduction in the μTBS, except in GOA2 specimens, which showed comparable outcomes among TC and non-TC specimens (p > 0.05). DC was significantly higher in control adhesive [46.8 (3.6)%] compared to GOA2 [37.7 (4.2)%] specimens, however DC was comparable among GOA1 [42.3 (2.9)%] and GOA2 [37.7 (4.2)%] specimens (p > 0.05) respectively. GO exhibited interaction within adhesive and tooth dentin comparable to control adhesive. Increasing GO content showed increase in μTBS of adhesive to dentin, but a decrease in degree of conversion. Under ideal conditions, experimental adhesive with 2% GO content showed acceptable bond strength and DC; and should be further assessed under dynamic conditions to recommend clinical use.

Original languageEnglish (US)
Article number115403
JournalMaterials Research Express
Volume7
Issue number11
DOIs
StatePublished - Nov 1 2020
Externally publishedYes

Bibliographical note

Publisher Copyright:
© 2020 The Author(s). Published by IOP Publishing Ltd.

Keywords

  • bond strength
  • degree of conversion
  • dentin bond
  • Graphene oxide
  • Micr-Raman Spectroscopy
  • resin adhesive

Fingerprint

Dive into the research topics of 'Influence of graphene oxide filler content on the dentin bond integrity, degree of conversion and bond strength of experimental adhesive. A SEM, micro-Raman, FTIR and microtensile study'. Together they form a unique fingerprint.

Cite this