Abstract
We report a case of incomplete left atrial appendage (LAA) closure after Watchman device (Atritech, Boston Scientific, Natrick, MA) implantation which subsequently developed a thrombus 3 years after the initial procedure. The thrombus resolved after a short period of anticoagulation with warfarin, and the LAA was successfully occluded with a second-generation Amplatzer Cardiac Plug (Amulet device, AGA, St Jude Medical, Minneapolis, MN). Incomplete LAA closure may be associated with increased risk of thrombus formation and further closure with a second device after a course of anticoagulation may be a reasonable and feasible strategy.
Original language | English (US) |
---|---|
Pages (from-to) | 321-327 |
Number of pages | 7 |
Journal | Catheterization and Cardiovascular Interventions |
Volume | 85 |
Issue number | 2 |
DOIs | |
State | Published - Feb 1 2015 |
Externally published | Yes |
Bibliographical note
Publisher Copyright:© 2014 Wiley Periodicals, Inc.
Keywords
- Fistula/shunts
- Left atrial appendage closure
- Transseptal cath