T1 - Impedance loading servo pump system for excised canine ventricle
AU - Sunagawa, K.
AU - Burkhoff, D.
AU - Lim, K. O.
AU - Sagawa, K.
PY - 1982
Y1 - 1982
N2 - To investigate ventricular-aterial system interaction, we have developed a hybrid-computer-controlled impedance loading servo pump system that enables us to impose a simulated arterial hydraulic impedance on an excised canine ventricle. An analog computer programmed to simulate a three-element Windkessel model of the arterial system computes instantaneous aortic flow from the instantaneous ventricular pressure. The time integral of this flow is used to command a volume servo pump system that controls the instantaneous ventricular volume. All parameter values in the loading system are controlled by a digital computer. The actual impedance spectrum generated by the system was reasonably close to that expected from the arterial model. The unique features of this system are the following. 1) The instantaneous volume of the ventricle, which is crucial information for the analysis of the ventricular-arterial system interaction, can be measured. 2) If needed, the arterial impedance model can easily be reprogrammed to generate more complex impedance spectra. 3) The vascular parameters can be made nonlinear or time varying through the digital computer control.
AB - To investigate ventricular-aterial system interaction, we have developed a hybrid-computer-controlled impedance loading servo pump system that enables us to impose a simulated arterial hydraulic impedance on an excised canine ventricle. An analog computer programmed to simulate a three-element Windkessel model of the arterial system computes instantaneous aortic flow from the instantaneous ventricular pressure. The time integral of this flow is used to command a volume servo pump system that controls the instantaneous ventricular volume. All parameter values in the loading system are controlled by a digital computer. The actual impedance spectrum generated by the system was reasonably close to that expected from the arterial model. The unique features of this system are the following. 1) The instantaneous volume of the ventricle, which is crucial information for the analysis of the ventricular-arterial system interaction, can be measured. 2) If needed, the arterial impedance model can easily be reprogrammed to generate more complex impedance spectra. 3) The vascular parameters can be made nonlinear or time varying through the digital computer control.
UR - http://www.scopus.com/inward/record.url?scp=0020173090&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0020173090&partnerID=8YFLogxK
U2 - 10.1152/ajpheart.1982.243.2.h346
DO - 10.1152/ajpheart.1982.243.2.h346
M3 - Article
C2 - 7114243
AN - SCOPUS:0020173090
SN - 0363-6135
VL - 12
SP - H346-H350
JO - American Journal of Physiology - Heart and Circulatory Physiology
JF - American Journal of Physiology - Heart and Circulatory Physiology
IS - 2
ER -