TY - JOUR
T1 - Hydrogen concentration analyses using SIMS and FTIR
T2 - Comparison and calibration for nominally anhydrous minerals
AU - Koga, Kenneth
AU - Hauri, Erik
AU - Hirschmann, Marc
AU - Bell, David
PY - 2003/2
Y1 - 2003/2
N2 - We report analyses of hydrogen abundance in experimentally annealed and natural mantle minerals using FTIR and use these data to establish calibration lines for measurement of H2O concentrations in olivine, pyroxenes, garnet, amphibole and mica by secondary ion mass spectrometry (SIMS). We have reduced the detection limit for H2O analysis by SIMS to 2-4 ppm H2O (by weight) through careful attention to sample preparation and vacuum quality. The accuracy of the SIMS calibrations depends on the choice of FTIR extinction coefficients; however, all of the calibrations reported here are shown to be consistent with measurements on standards whose H2O abundance has been determined independently via manometry or nuclear reaction analysis. The resulting calibrations are accurate to 10-30% at the 95% confidence limit, with improvements possible through the use of higher-H 2O standards. Using our SIMS calibration, we determined hydrogen concentrations in coexisting olivine, orthopyroxene, and glass from a single melting experiment at 2 GPa and 1380°C. Olivine/melt and orthopyroxene/melt partition coefficients are equal to 0.0020 ± 0.0002 and 0.0245 ± 0.0015, respectively, and the orthopyroxene/olivine coefficient is 12 ± 4 (2σ uncertainties).
AB - We report analyses of hydrogen abundance in experimentally annealed and natural mantle minerals using FTIR and use these data to establish calibration lines for measurement of H2O concentrations in olivine, pyroxenes, garnet, amphibole and mica by secondary ion mass spectrometry (SIMS). We have reduced the detection limit for H2O analysis by SIMS to 2-4 ppm H2O (by weight) through careful attention to sample preparation and vacuum quality. The accuracy of the SIMS calibrations depends on the choice of FTIR extinction coefficients; however, all of the calibrations reported here are shown to be consistent with measurements on standards whose H2O abundance has been determined independently via manometry or nuclear reaction analysis. The resulting calibrations are accurate to 10-30% at the 95% confidence limit, with improvements possible through the use of higher-H 2O standards. Using our SIMS calibration, we determined hydrogen concentrations in coexisting olivine, orthopyroxene, and glass from a single melting experiment at 2 GPa and 1380°C. Olivine/melt and orthopyroxene/melt partition coefficients are equal to 0.0020 ± 0.0002 and 0.0245 ± 0.0015, respectively, and the orthopyroxene/olivine coefficient is 12 ± 4 (2σ uncertainties).
KW - Hydrogen
KW - Ion probe
KW - Mantle
KW - Mineral
KW - SIMS
KW - Water
UR - http://www.scopus.com/inward/record.url?scp=72749099582&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=72749099582&partnerID=8YFLogxK
U2 - 10.1029/2002GC000378
DO - 10.1029/2002GC000378
M3 - Article
AN - SCOPUS:72749099582
SN - 1525-2027
VL - 4
JO - Geochemistry, Geophysics, Geosystems
JF - Geochemistry, Geophysics, Geosystems
IS - 2
M1 - 1019
ER -