High speed differential to single-ended amplifier for instrumentation applications

Douglas Dean, Ramesh Harjani

Research output: Contribution to journalConference articlepeer-review

Abstract

This paper describes a 1 GHz differential to single-ended amplifier for instrumentation. The unity gain amplifier can directly drive a 50 Ω load with a common-mode voltage centered at ground and can accept up to a 1 VP-P input signal. The measured noise floor is below 20 nV/√Hz for most of the bandwidth and the common-mode rejection is 20dB at 1 GHz.

Original languageEnglish (US)
Pages (from-to)III-459-III-462
JournalProceedings - IEEE International Symposium on Circuits and Systems
Volume3
DOIs
StatePublished - 2000
EventProceedings of the IEEE 2000 International Symposium on Circuits and Systems, ISCAS 2000 - Geneva, Switz, Switzerland
Duration: May 28 2000May 31 2000