High-performance and low-cost lung cancer sensor array based on self-assembled graphene

B. Zhang, Tianhong Cui

Research output: Contribution to journalConference article

1 Citation (Scopus)

Abstract

The lung cancer sensor array (LCSA) based on layer-by-layer (LbL) self-assembled graphene presented in this paper is capable of detecting different lung cancer biomarkers selectively with advantages of high sensing performance and low cost due to graphene inherent properties and self assembly technique. According to the resistance change of graphene, the detection limit of LCSA is down to 0.1 pg/mL.

Original languageEnglish (US)
Article number7051027
Pages (from-to)600-603
Number of pages4
JournalProceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)
Volume2015-February
Issue numberFebruary
DOIs
StatePublished - Jan 1 2015
Event2015 28th IEEE International Conference on Micro Electro Mechanical Systems, MEMS 2015 - Estoril, Portugal
Duration: Jan 18 2015Jan 22 2015

Fingerprint

Graphite
Sensor arrays
lungs
Graphene
graphene
cancer
sensors
Costs
biomarkers
Tumor Biomarkers
Self assembly
self assembly
assembly
costs

Cite this

High-performance and low-cost lung cancer sensor array based on self-assembled graphene. / Zhang, B.; Cui, Tianhong.

In: Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS), Vol. 2015-February, No. February, 7051027, 01.01.2015, p. 600-603.

Research output: Contribution to journalConference article

@article{24f56f42b6624d9591f6c62dc558dfc1,
title = "High-performance and low-cost lung cancer sensor array based on self-assembled graphene",
abstract = "The lung cancer sensor array (LCSA) based on layer-by-layer (LbL) self-assembled graphene presented in this paper is capable of detecting different lung cancer biomarkers selectively with advantages of high sensing performance and low cost due to graphene inherent properties and self assembly technique. According to the resistance change of graphene, the detection limit of LCSA is down to 0.1 pg/mL.",
author = "B. Zhang and Tianhong Cui",
year = "2015",
month = "1",
day = "1",
doi = "10.1109/MEMSYS.2015.7051027",
language = "English (US)",
volume = "2015-February",
pages = "600--603",
journal = "Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)",
issn = "1084-6999",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "February",

}

TY - JOUR

T1 - High-performance and low-cost lung cancer sensor array based on self-assembled graphene

AU - Zhang, B.

AU - Cui, Tianhong

PY - 2015/1/1

Y1 - 2015/1/1

N2 - The lung cancer sensor array (LCSA) based on layer-by-layer (LbL) self-assembled graphene presented in this paper is capable of detecting different lung cancer biomarkers selectively with advantages of high sensing performance and low cost due to graphene inherent properties and self assembly technique. According to the resistance change of graphene, the detection limit of LCSA is down to 0.1 pg/mL.

AB - The lung cancer sensor array (LCSA) based on layer-by-layer (LbL) self-assembled graphene presented in this paper is capable of detecting different lung cancer biomarkers selectively with advantages of high sensing performance and low cost due to graphene inherent properties and self assembly technique. According to the resistance change of graphene, the detection limit of LCSA is down to 0.1 pg/mL.

UR - http://www.scopus.com/inward/record.url?scp=84931028884&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84931028884&partnerID=8YFLogxK

U2 - 10.1109/MEMSYS.2015.7051027

DO - 10.1109/MEMSYS.2015.7051027

M3 - Conference article

VL - 2015-February

SP - 600

EP - 603

JO - Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)

JF - Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)

SN - 1084-6999

IS - February

M1 - 7051027

ER -